Electrical Characteristic

Ta = –40 to 85°C

Item Symbol

V

CC

(V) *

Min

Typ

Max

Unit

Test condition

1.65 to 1.95

V

CC

×

0.75

2.5 — —

1.75

3.3 — —

2.31

V

T

+

5.0 — —

3.50

1.65 to 1.95 V

CC

×

0.25 —

2.5 0.75 — —

3.3 0.99 — —

V

T

5.0 1.5 — —

1.65 to 1.95

0.1

V

CC

×

0.4

2.5 0.25 — 1.0

3.3 0.33 — 1.32

Threshold

voltage

V

T

5.0 0.5 — 2.0

V

Min to Max

V

CC

–0.1 —

I

OH

= –50

µ

A

1.65 1.4 — —

I

OH

= –1 mA

2.3 2.0 — —

I

OH

= –2 mA

3.0 2.48 — —

I

OH

= –6 mA

V

OH

4.5 3.8 — —

I

OH

= –12 mA

Min to Max

0.1

I

OL

= 50

µ

A

1.65 — — 0.3

I

OL

= 1 mA

2.3 — — 0.4

I

OL

= 2 mA

3.0 — —

0.44

I

OL

= 6 mA

Output voltage

V

OL

4.5 — —

0.55

V

I

OL

= 12 mA

Input current

I

IN

0 to 5.5

±1

µ

A V

IN

= 5.5 V or GND

Quiescent
supply current

I

CC

5.5 — — 10

µ

A

V

IN

= V

CC

or GND,

I

O

= 0

Output leakage
current

I

OFF

0 — — 5

µ

A V

IN

or V

O

= 0 to 5.5 V

Input capacitance

C

IN

3.3 — 3.0 — pF

V

IN

= V

CC

or GND

Note: For conditions shown as Min or Max, use the appropriate values under recommended operating conditions.