background image

VENTING INFORMATION FOR 2" VENTS

CROSS REFERENCE AND SPECIFICATIONS

Residential water heaters

from Rheem

Rheem Water Heating • 101 Bell Road, Montgomery, AL 36117-4305
800-621-5622 • [email protected] • www.rheem.com

Rheem Canada Ltd./Ltée • Water Heater Division
128 Barton Street West, Hamilton, Ontario L8N 3P3

Not all models are available in Canada.

Printed in U.S.A.

05/07 WP

Form No. 101-65 Rev. 3

RHEEM INDUCED DRAFT GAS POWERVENT

Guardian System

Air / fuel shut-off
system offers
double protection

Maintenance free –
no filter to clean

Flammable Vapor
Detection Sensor

Protective control system that
disables the heater in the
presence of flammable vapor
accumulation

Flexible Venting Options

Long venting lengths up to 100 feet

PVC, ABS, or CPVC vent pipe options

Vertical or horizontal termination

New Quiet Blower

Less noise than ever before

Self-Diagnostic System

Integrated self-diagnostic
system control takes the
guess work away

Environmentally
Friendly Burner

Low NOx design for low
nitrous oxide emissions

High Altitude Compliant

Tall models are certified for applications up to
7,700 feet above sea level

Short models: certified up to 6,000 feet above
sea level

Self-Cleaning

EverKleen

patented system fights sediment

build-up

Reduces fuel costs

Provides more hot water

Longer Life

Patented magnesium anode rod design
incorporates a special resistor that protects
the tank from corrosion.

Provides longer
tank life than using
standard magnesium
anode rods

HOT

WATER

CONNECTION

COLD

WATER

CONNECTION

POWER VENT

ASSEMBLY

C

B

F

A

D

G

G

E

T&P FITTING

3/4" N.P.T.

1/2"

Energy Factor and

Average Annual

Operating Costs based

on D.O.E. (Department

of Energy) test proce-

dures. D.O.E. national

average fuel rate

natural gas 91¢/therm;

LP $1.23/gallon.

6-Year Limited Tank

and Parts Warranty

See Residential Warranty
Information Brochure for

complete warranty information.

DESCRIPTION

FEATURES

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)

ENERGY INFO.

NEW

HT. TO

HT. TO

WATER

HT. TO

WATER

PREVIOUS

FVIR

GAS INPUT IN

RECOVERY IN

FIRST HOUR

TOP OF

TANK

GAS

CONN.

SIDE T&P

CONN.

SHIP.

ENERGY

AVG. ANN.

GAL.

MODEL

MODEL

THOUS. BTU/HR.

G.P.H. 90° RISE

DEL. G.P.H.

ASSEMBLY

HT.

DIAM.

CONN.

CNTR.

VALVE

SIZE

WT.

FACTOR

OPER. COSTS

CAP.

NUMBER

NUMBER

NAT.

LP

NAT.

LP

NAT.

A

B

C

D

E

F

G

(LBS)

NAT.

NAT. GAS

40

41VRP40

42VP40F

40

40

40.4

40.4

68

69-1/4

59

19-3/4

14

8

53-1/2

3/4

140

0.64

$213

50

41VRP50

42VP50F

42

42

42.4

42.4

87

68-1/4

58

21-3/4

14

8

52-1/2

3/4

170

0.64

$213

40

NEW!

42VP40SF

36

34

36.4

34.3

71

61-1/2

50-1/2

20-1/4

14

8

44

3/4

152

0.64

$213

50

NEW!

42VP50SF

36

34

36.4

34.3

85

61-1/2

50-1/2

22-1/4

14

8

44

3/4

176

0.62

$220

T
Y
P
E

TALL

SHORT

NUMBER OF

MINIMUM

MAXIMUM

90° ELBOWS

NUMBER

PIPE

PIPE

WITH VENT

OF 45°

LENGTH

LENGTH

TERMINAL

ELBOWS

REQ. (FT.)

(FT.)

One (1)

None

4.0

44.0

One (1)

One (1)

4.0

41.0

Two (2)

None

4.0

38.0

Two (2)

One (1)

4.0

35.0

Three (3)

None

4.0

32.0

For the 2" vent, one 90° elbow is approximately equal to 6 feet of
pipe. One 45° elbow is approximately equal to 3 feet of pipe.

VENTING INFORMATION FOR 3" VENTS

NUMBER OF

MINIMUM

MAXIMUM

90° ELBOWS

NUMBER

PIPE

PIPE

WITH VENT

OF 45°

LENGTH

LENGTH

TERMINAL

ELBOWS

REQ. (FT.)

(FT.)

One (1)

None

5.0

95.0

One (1)

One (1)

5.0

92.5

Two (2)

None

5.0

90.0

Two (2)

One (1)

5.0

87.5

Three (3)

None

5.0

85.0

Three (3)

One (1)

5.0

82.5

Four (4)

None

5.0

80.0

Four (4)

One (1)

5.0

77.5

Five (5)

None

5.0

75.0

For the 3" vent, one 90° elbow is approximately equal to 5 feet of
pipe. One 45° elbow is approximately equal to 2.5 feet of pipe.

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.

Advertising