Chapter 6: Calibration

33

Log calibration

The ST30 Bidata should not be used for navigational purposes until the
transducer paddlewheel has been calibrated to suit the characteristics of
the vessel.

This is a simple operation and is carried out as follows:

1.

Choose two charted points that are approximately 1nm apart.

Approximately 1Nm

Point 1

Point 2

D699

2.

Choosing a time when the tidal flow is at a minimum, go from point 1
to point 2 and record the ST30 Bidata trip distance.

3.

Go from point 2 to point 1 and record the trip distance.

4.

Add the two distances together and divide by two to obtain an
average distance.

5.

Measure the distance between the two points on a chart.

6.

The correction factor (CF) can now be calculated.

CF =

Charted Distance

Average Distance