1. STOP! Read the safety information above.

2. Set the thermostat on the lowest setting.

3. Turn off all electric power to the appliance.

4. Remove heater door panel.

5. This appliance is equipped with an ignition device

which automatically light the pilot. Do not try to light
the pilot by hand.

6. For Models 514-724 with Honeywell Gas Valve.

Push in gas control knob slightly and turn clockwise

to “OFF”. Knob cannot be turned to “OFF”

unless knob is pushed in slightly. Do not Force.

GAS CONTROL KNOB
SHOWN IN “ON”
POSITION

GAS INLET

Fig. #8219.0

For Models 514-724 with Robertshaw Gas Valve.
Turn Gas control knob clockwise to “OFF”.

GAS CONTROL
KNOB SHOWN
IN “ON” POSITIONS

GAS INLET

Fig. # 8080.0

For Models 824
Turn main gas shut-off and pilot shut-off valves counter
clockwise

to “OFF”.

TO PILOT

PILOT SHUT-OFF
VALVE CONTROL

MAIN GAS SHUT-OFF

SHOWN IN THE

VALVE SHOWN IN

“ON” POSITION

THE “ON” POSITION

GAS
INLET

Fig. # 8220.0

7. Wait fire (5) minutes to clear out any gas. Then

smell for gas, including near the floor. If you smell
gas, STOP! Follow "B" in the safety information
above on this label. If you don't smell gas, go to the
next step

8. For Models 514-724

Turn gas control knob counter clockwise
to “On”

For Model 824
Turn main gas shut-off and pilot shut-off valves
clockwise

to on.

9. Replace heater door panel.

10. Turn on all electric power to the appliance.

11. Set thermostat to desired setting.

12. If the appliance will not operate, follow the instruc-

tions “To Turn Off Gas to Appliance” and call your
service technician or gas supplier.

OPERATING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

Push in gas control knob slightly and turn clock-
wise

to “OFF”.

For Models 824
Turn main gas shut-off and pilot shut-off valves
counter clockwise

to “OFF”.

5. Replace heater door panel.

1. Set the thermostat to the lowest setting.

2. Turn off all the electric power to the appliance if

service is to be performed.

3. Remove heater door panel.
4. For Models 514-724

Advertising