Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

Water Temperature Control

Controller



Controller Cable

Safety Devices


Clearances from Combustibles
(suitable for closet, attic, and
crawl space installations)

Clearances from Non-combustibles



Min. / Max. Gas Supply Pressure
(sea level)

Manifold Gas Pressure (inches W.C.)


NOx

Warranty

Simulation feed forward and feedback

MC-91-1US (part of the front panel)
Deluxe controller: MC-100V-1US (optional)
Bathroom controller: BC-100V-1US (optional)
MCC-91-1US (for commercial applications)

Non-polarized two-core cable, minimum 22 AWG

• Flame failure - Flame Rod

• Boiling protection

• Combustion fan rpm check

• Over current - glass fuse (3 amp)
• Top of heater - 6 inches

• Front of heater - 6 inches

• Sides of heater - 2 inches
• Top of heater - 2 inches

• Front of heater - 6 inches

• Sides of heater - 1/2 inch
Natural Gas: min 5” W.C.

max 10.5” W.C.

Propane Gas: min 8” W.C.

max 13.5” W.C.

Natural Gas: high fire 3.4” W.C.

low fire 0.55” W.C.

Propane Gas: high fire 5.4” W.C.

low fire 0.96” W.C.

Meets California and Texas NOx Emission Rules

Heat exchanger: 12 years* for residential and 5 years* for
commercial and hydronic applications; (10 years* if used with the
Rinnai Hydronic Air Handler); all other parts 5 years*; labor 1 year;
(* 3 years if used as a circulating water heater within a circulation
loop, when the water heater is in series with a circulation system
and all circulating water flows through the water heater)

DIMENSIONS

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.

• Remaining flame (OHS)

• Thermal fuse

• Automatic frost protection

• Back of heater - 0 inches

• Ground / bottom - 12 inches

• From vent pipe - 0 inches
• Back of heater - 0 inches

• Ground / bottom - 12 inches

• From vent pipe - 0 inches

The wall bracket is adjustable to allow
an additional 1.57 inches (40 mm).

WEIGHT: 53 LBS (24 KG)

A

C D

E

H

J

F

G I

DIM DESCRIPTION R75LSi

in (mm)

A Width

14

(355.6)

B Depth *

9.6 (244.5)

C Height - Unit

22.9 (582)

D Height - with brackets

25.5 (648.2)

E Hot Water Outlet - from wall *

3.6 (91)

F Hot Water Outlet - from center

4.3 (110)

G Cold Water Inlet - from wall *

2.8 (70)

H Cold Water Inlet - from center

1.1 (27)

I Gas Connection - from wall *

3.9 (99)

J Gas Connection - from center

3.5 (89)

K

From base to gas connection

1.6 (40)

From base to cold connection

2.0 (50)

From base to hot connection

1.6 (41)

B

K

Advertising