Raypak XPAK 120 User Manual

Page 6

Advertising
background image

Technical level

Setting of parameters 1-17.

Holiday setting

Heating and hot water are disabled. Only the

freeze protection function remains enabled.

After setting the parameters, turn the SELECT knob

back to “RUN.”

Setting the comfort temperature

Turn the left-hand knob (SELECT) to

and turn the EDIT knob to set the required tempera-

ture from 40°F to 104°F (5°C to 40°C). After setting

the parameter, turn the SELECT knob back to “RUN.”

Setting the night setback temperature

Turn the left-hand knob (SELECT) to

and turn the EDIT knob to set the required tempera-

ture from 40°F to 104°F (5°C to 40°C). After setting

the parameter, turn the SELECT knob back to “RUN.”

Setting the domestic hot water temperature

Turn the left-hand knob (SELECT) to and

turn the EDIT knob to set the required temperature

from 95°F to 122°F (35°C to 50°C). After setting the

parameter, turn the SELECT knob back to “RUN.”

Setting the day of the week

Turn the left-hand knob (SELECT) to “1….7” and turn

the EDIT knob to set the required day of the week.

After setting the parameter, turn the SELECT knob

back to “RUN.”

6

“ ”

“ ”

Automatic operation - heating according to

program 2

Heating with program 2. Domestic hot water produc-

tion enabled.

Continual heating in comfort mode (manual)

24-hour heating at comfort temperature. Domestic

hot water production enabled.

Continual heating in setback mode (manual)

24-hour heating at setback temperature. Domestic

hot water production enabled.

Summer mode

No heating (only freeze protection). Domestic hot

water production enabled.

PL

HO

“ ”

RUN MODE

With the left-hand knob (SELECT) turned to “RUN,”

the control panel displays the information required to

check the status of the control panel and boiler. The

information is displayed in Fig. 3 on page 5.

CONTROL PANEL OPERATING MODE

SETTINGS

Turn the left-hand knob (SELECT) to “MODE” and

turn the right-hand knob (EDIT) to set one of the fol-

lowing

operating modes:

Standby / OFF

Heating and hot water are disabled. Only the freeze

protection function remains enabled.

Automatic operation - heating according to

program 1

Heating with program 1. Domestic hot water produc-

tion enabled.

Advertising