Rinnai 556FAIII User Manual

556faiii

Advertising
background image

FEATURES

provides precise gas flow

detects temperature change in 1/2 of a degree

monitors and controls combustion fan

reduces noise through use of swept blades in convection fan; and
through the design of the combustion chamber and heat exchanger
which silently expand or contract due to temperature changes

continually monitors functions; provides auto shutdown codes; indicates
when air filter needs cleaning

Linear function modulation:

Negative coefficient thermistor:

Variable speed inducer motor:

Quiet operation:



Self diagnostic electronics:

556FAIII

Type of Appliance

Rinnai Model Number

Gas Rate Input (BTU/hour)

Gas Rate Output (BTU/hour)

AFUE Rating

Minimum Gas Supply Pressure

Maximum Gas Supply Pressure

Electrical Connection

Gas Connection

Combustion System

Ignition System

Fan CFM Output:

Temperature Settings

Temperature Control

Humidifier Tray

Weight

Clearance from Combustibles


Noise Level

Warm Air Outlet

Direct vent wall furnace suitable for homes, apartments, and
condominiums; modular/mobile home approved; forced combustion,
forced convection

RHFE-556FA-N (Natural gas)

RHFE-556FA-P (Propane)

Low - 8,200

Low - 8,200

High - 21,500

High - 20,700

Low - 6,640

Low - 6,640

High - 17,420

High - 16,770

80.6% 81.0%

5 in (127 mm) W.C.

11 in (279 mm) W.C.

10.5 in (267 mm) W.C

13 in (330 mm) W.C.

AC 120V, 60 Hz, 52 watts

1/2 inch FNPT

Stainless steel inshot burners

Direct spark

Low: 110.5

High: 162.7

Low (LO): minimum combustion
60° - 80° F in 4° increments

High (HI): maximum combustion

Electronic thermostat

Enameled tray with capacity of 3 pints (1.3 liters)

Approximately 51 lbs (23 kg)

Side: 2 inches (50 mm)

Top: 10 inches (250 mm)

Front: 40 inches (1 m)

32 - 41 dB(A)

Bottom front louvers

© 2005 Rinnai Corporation

RHFE-556FAIII SP-1 4/2007

Advertising