En 8 8, Recycling version air outlet – Rangemaster GLX490 RM User Manual

Page 8

Advertising
background image

EN

8

8

RECYCLING VERSION AIR OUTLET

To install the hood in recycling version, the optional charcoal
filter kit must be purchased.

• Remove the chimney angle bracket.
• Screw the filter cover onto the air outlet, using four screws 12c

(2.9 x 12.5).

• Fix the air outlet grid 8 on the recirculation air outlet using the

2 screws 12d (2,9 x 9,5) provided.

16

12c

12d

8

RECIRCULATION VERSION AIR OUTLET

• Insert the connection extension pieces laterally 14.1 in connec-

tion 15.

• Insert the Connector 15 into the Support bracket 7.3 and fix it

with a screw.

• Make sure that the outlet of the extension pieces 14.1 is hori-

zontally and vertically aligned with the chimney outlets.

• Connect the air outlet connection 15 to the hood body outlet

using either a flexible or rigid pipe ø 150 mm, the choice of
which is left to the installer.

• Ensure that the activated charcoal filters have been inserted.

ø 150

15

14.1

7.3

ELECTRICAL CONNECTION

• Connect the hood to the mains supply.
• Open the upper panel by pressing the A-key (See Part “USE” )

for at least 2 seconds.

• Remove the metal filters (See Part “MAINTENANCE”) and

make sure that the connector piece of the supply cable is cor-
rectly inside the hood socket.

Advertising