7



WARNING: ALL WIRING AND INSTALLATION MUST BE

SUPERVISED BY A SUITABLY QUALIFIED PERSON.

WARNING: DO NOT INSTALL THIS SHOWER WHERE IT MAY BE

SUBJECTED TO FREEZING CONDITIONS

We recommend that the installation is done in the following sequence.

a. Fixing the shower to the wall b. Plumbing c. Electrical connections

a. FIXING THE SHOWER TO THE WALL

1. Position the riser rail at the height recommended in diagram 5 and

mark its position (also see separate accessories fitting instructions).

2. Position the heater so that the top of the unit is horizontal and level

with, or a maximum of 0.6 metres (2ft) below the top of the
riser rail
. Choose a flat piece of wall to avoid the possibility of
distorting the backplate thus making the front cover a poor fit.

3. Adjust the position to get the most convenient arrangement taking

the following into account.

The possible need to use the handset over the sink for hair washing etc.

The heater must not be mounted in the direct spray from the handset.

The handset must not be able to come into contact with used water in the cubicle, bath or

basin. If it can, even after the hose has been retained by the soap dish (see separate
accessories fitting instructions sheet) then a vacuum breaker must be fitted.

4. Fix the riser rail with screws provided (see separate instructions supplied with accessories).

5. Decide the position of the electrical cable into the unit. If top or bottom entry is chosen

(according to diagram 4), cut away the walls in the backplate as shown in diagram 6.

6. Decide the position of entry of the cold water pipe into the unit.

If top, cut away the backplate.
If rear, please read the section on plumbing.
If bottom, remove the front cover (complete with knobs) and cut away the detachable corner

section as shown.

HOW TO INSTALL YOUR EXPRESSIONS 550S SHOWER