Emi and environmental type tests, Ruggedserver™ rs416 – RuggedCom RuggedServer RS416 User Manual

Page 6

Advertising
background image

www.RuggedCom.com

6

RuggedServer™ RS416

RuggedServer™ RS416

Modular 16-Port Serial Device Server with Integrated Managed Ethernet Switch

EMI and Environmental Type Tests

Environmental Type Tests

Test

Description

Test Levels

IEC 60068-2-1

Cold Temperature

Test Ad

-40°C, 16 Hours

IEC 60068-2-2

Dry Heat

Test Bd

+85°C, 16 Hours

IEC 60068-2-30

Humidity (Damp Heat, Cyclic)

Test Db

95% (non-condensing), 55°C , 6 cycles

IEC 60255-21-1

Vibration

2g @ (10 - 150) Hz

IEC 60255-21-2

Shock

30g @ 11mS

IEC 61850-3 EMI TYPE TESTS

TEST

Description

Test Levels

Severity Levels

IEC 61000-4-2

ESD

Enclosure Contact

+/- 8kV

4

Enclosure Air

+/- 15kV

4

IEC 61000-4-3

Radiated RFI

Enclosure ports

20 V/m

Note 1

IEC 61000-4-4

Burst (Fast Transient)

Signal ports

+/- 4kV @ 2.5kHz

Note 1

D.C. Power ports

+/- 4kV

4

A.C. Power ports

+/- 4kV

4

Earth ground ports

+/- 4kV

4

IEC 61000-4-5

Surge

Signal ports

+/- 4kV line-to-earth, +/- 2kV line-to-line

4

D.C. Power ports

+/- 2kV line-to-earth, +/- 1kV line-to-line

3

A.C. Power ports

+/- 4kV line-to-earth, +/- 2kV line-to-line

4

IEC 61000-4-6

Induced (Conducted) RFI

Signal ports

10V

3

D.C Power ports

10V

3

A.C. Power ports

10V

3

Earth ground ports

10V

3

IEC 61000-4-8

8 Magnetic Field

Enclosure ports

40 A/m continuous, 1000 A/m for 1 s

Note 1

1000 A/m for 1 s

5

IEC 61000-4-29

Voltage Dips & Interrupts

D.C. Power ports

30% for 0.1s, 60% for 0.1s, 100% for 0.05s

N/A

A.C. Power ports

30% for 1 period, 60% for 50 periods

N/A

IEC 61000-4-11

100% for 5 periods, 100% for 50 periods

N/A

IEC 61000-4-12

Damped Oscillatory

Signal ports

2.5kV common, 1kV diff. mode@1MHz

3

D.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

3

A.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

3

IEC 61000-4-16

Mains Frequency Voltage

Signal ports

30V Continuous, 300V for 1s

4

D.C. Power ports

30V Continuous, 300V for 1s

4

IEC 61000-4-17

Ripple on D.C. Power Supply

D.C. Power ports

10%

3

IEC 60255-5

Dielectric Strength

Signal ports

2kVac (Fail-Safe Relay output)

N/A

D.C. Power ports

2kVac

N/A

A.C. Power ports

2kVac

N/A

IEC 60255-5

H.V. Impulse

Signal ports

5kV (Fail-Safe Relay output)

N/A

D.C. Power ports

5kV

N/A

A.C. Power ports

5kV

N/A

IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS

2

Test

Description

Test Levels

IEEE C37.90.3

ESD

Enclosure Contact

+/-2kV, +/-4kV, +/- 8kV

Enclosure Air

+/-4kV, +/-8kV, +/-15kV

IEEE C37.90.2

Radiated RFI

Enclosure ports

35 V/m

IEEE C37.90.1

Fast Transient

Signal ports

+/- 4kV @ 2.5kHz

D.C. Power ports

+/- 4kV

A.C. Power ports

+/- 4kV

Earth ground ports3

+/- 4kV

IEEE C37.90.1

Oscillatory

Signal ports

2.5kV common mode @1MHz

D.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

A.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

IEEE C37.90

H.V. Impulse

Signal ports

5kV (Fail-Safe Relay output)

D.C. Power ports

5kV

A.C. Power ports

5kV

IEEE C37.90

Dielectric Strength

Signal ports

2kVac

D.C. Power ports

2kVac

A.C. Power ports

2kVac

Notes:

1. Ruggedcom specified severity levels

2. Meets Class 2 requirements for an all fiber configuration. Class 1 for copper ports.