Technical specifications, Ruggedswitch, Rs940g – RuggedCom RS940G User Manual

Page 6

Advertising
background image

www.RuggedCom.com

6

RuggedSwitch

®

RS940G

RuggedSwitch

®

RS940G

8-Port Managed Gigabit Ethernet Switch, 128-bit Encryption

Technical Specifications

Power Supply

„

„ „

Power Consumption: 18W Max

„

„ „

24VDC: 10-36 VDC, 0.4A

„

„ „

48VDC: 36-72 VDC, 0.2A

„

„ „

HI Voltage AC/DC: 88-300VDC or 85-264VAC

Critical Alarm Relay

„

„ „

Form-C failsafe contact relay: 1A@30VDC

Physical

„

„ „

Height: 7.4”

„

„ „

Width: 2.6”

„

„ „

Depth: 5.0”

„

„ „

Weight: 2.7lbs

„

„ „

Ingress Protection: IP40 (1mm objects)

„

„ „

Enclosure: 20 AWG galvanized steel enclosure

„

„ „

Mounting: DIN rail or panel mounted

Switch Properties

„

„ „

Switching method: Store & Forward

„

„ „

Switching latency: 7 us

„

„ „

Switching bandwidth: 16Gbps

„

„ „

MAC addresses: 8192

„

„ „

MAC address table size: 32kbytes

„

„ „

Priority Queues: 4

„

„ „

Frame buffer memory: 2 Mbit

„

„ „

Simultaneous VLANs: 255

„

„ „

VLAN ID Range: 1 to 4094

„

„ „

IGMP multicast groups: 256

„

„ „

Port rate limiting: 128kbps, 256, 512, 4, 8Mbps

„

„ „

No head of line blocking

Approvals

„

„ „

Hazardous Locations: Class 1, Division 2

„

„

ISO: Designed and manufactured using a ISO9001:2000

certified quality program

„

„ „

CE Marking

„

„ „

Emissions: FCC Part 15 (Class A),

EN55022 (CISPR22 Class A)

„

„ „

Safety: cCSAus (Compliant with CSA C22.2 No. 60950, UL

60950, EN60950)

„

„ „

Laser Eye Safety (FDA/CDRH): Complies with 21

CFR Chapter1, Subchapter J.

Warranty

„

„ „

5 Years - Applicable to design and manufacturing

related product defects.

Network Management

„

„ HTTP graphical web-based, SSL (128-bit encryption)

„

„ SNMP v1, v2c, v3 (56-bit encryption)

„

„ Telnet, VT100, SSH/SFTP (128-bit encryption)

„

„ Command Line Interface (CLI)

„

„ RSA Key Management (1024 bit key)

„

„ Authentication and Accounting - TACACS+ (encrypted),

RADIUS client, PPP

EMI Immunity and Environmental Compliance

„

„ IEC 61000-6-2 Industrial (Generic)

„

„ IEC 61800-3 Industrial (Variable Speed Drive Systems)

„

„ IEwC 61850-3 Electric Utility Substations

„

„ IEEE 1613 Electric Utility Substations

„

„ NEMA TS 2 Traffic Control Equipment (pending)

IEEE Compliance

„

„ 802.3-10BaseT

„

„ 802.3u-100BaseTX, 100BaseFX

„

„ 802.3x-Flow Control

„

„ 802.3z-1000BaseLX

„

„ 802.3ab-1000BaseTX

„

„ 802.3ad-Link Aggregation

„

„ 802.1D-MAC Bridges

„

„ 802.1D-Spanning Tree Protocol

„

„ 802.1p-Class of Service

„

„ 802.1Q-VLAN Tagging

„

„ 802.1w-Rapid Spanning Tree Protocol

„

„ 802.1x-Port Based Network Access Control

„

„ 802.1Q-2005 (formerly 802.1s) MSTP

IETF RFC Compliance

„

„ RFC768-UDP

„

„ RFC783-TFTP

„

„ RFC791-IP

„

„ RFC792-ICMP

„

„ RFC793-TCP

„

„ RFC826-ARP

„

„ RFC854-Telnet

„

„ RFC894-IP over Ethernet

„

„ RFC1112-IGMP v1

„

„ RFC1519-CIDR

„

„ RFC1541-DHCP (client)

„

„ RFC2030-SNTP

„

„ RFC2068-HTTP

„

„ RFC2236-IGMP v2

„

„ RFC2284-EAP

„

„ RFC2475-Differentiated Services

„

„ RFC2865-RADIUS

„

„ RFC3414-SNMPv3-VSM

„

„ RFC3415-SNMPv3-VACM

IETF SNMP MIBS

„

„ RFC1493-BRIDGE-MIB

„

„ RFC1907-SNMPv2-MIB

„

„ RFC2012-TCP-MIB

„

„ RFC2013-UDP-MIB

„

„ RFC2578-SNMPv2-SMI

„

„ RFC2579-SNMPv2-TC

„

„ RFC2819-RMON-MIB

„

„ RFC2863-IF-MIB

„

„ draft-ietf-bridge-rstpmib-03-BRIDGE-MIB

„

„ draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB

„

„ IANAifType-MIB

Advertising