P36 - P36D Zero Clearance Direct Vent Gas Fireplace

Model

P36-NG4

P36-LP4

P36D-NG1

P36D-LP1

Fuel Type

Natural Gas

Propane

Natural Gas

Propane

Minimum Supply
Pressure

5” W.C.

(1.25 kPa)

12” W.C.

(3.00 kPa)

5” W.C.

(1.25 kPa)

12” W.C.

(3.00 kPa)

Manifold
Pressure - High

3.8” W.C.

(0.95 kPa)

11” W.C.

(2.74 kPa)

3.8” W.C.

(0.95 kPa)

11” W.C.

(2.74 kPa)

Manifold
Pressure - Low

1.1” W.C.

(0.27 kPa)

2.9” W.C.

(0.72 kPa)

1.1” W.C.

(0.27 kPa)

2.9” W.C.

(0.72 kPa)

Orifi ce Size

#37 DMS

#52 DMS

#37 DMS

#52 DMS

Minimum Input

15,500 BTU/h

(4.54 kW)

15,000 BTU/h

(3.96 kW)

15,500 BTU/h

(4.54 kW)

15,000 BTU/h

(3.96 kW)

Maximum Input

30,000 BTU/h

(8.79 kW)

30,000 BTU/h

(8.79 kW)

30,000 BTU/h

(8.79 kW)

30,000 BTU/h

(8.79 kW)

Vent Sizing

4” Inner / 6 5/8”

Outer

4” Inner / 6 5/8”

Outer

4” Inner / 6 5/8”

Outer

4” Inner / 6 5/8”

Outer

A

D

C

F

E

A

B

Unit Dimensions

Description

P36

P36D

A

Front Face Width

36” (914mm)

36” (914mm)

B

Rear Firebox Width

33-1/4” (838mm)

33-1/4” (838mm)

C

Front Face Height

30-1/2” (775mm)

30-1/2” (775mm)

D

Height w/ Standoff

36” (914mm)

37” (940mm)

E

Unit Depth

12-3/4” (324mm)

17-1/8” (435mm)

F

Height to Vent

32-1/2” (826mm)

32-1/2” (826mm)

Framing Dimensions

Description

P36

P36D

G

Framing Width*

36-1/4” (921mm)

36-1/4” (921mm)

H

***

Framing Height*

***

36-1/4” (921mm)

***

37-1/4” (946mm)

***

I

Framing Depth*

12-3/4” (324mm)

17-1/8” (435mm)

J

Corner Wall Length

42-7/16” (1078mm)

48” (1219mm)

K

C o r n e r F a c i n g Wa l l
Width

60” (1524mm)

68” (1727mm)

L

Framed Chase Ceiling

46” (1168mm)

46-1/2” (1181mm)

M

Vent Centerline Height

40-1/2” (1029mm)

40-1/2” (1029mm)

N

Gas Connection Height

2” (51mm)

2” (51mm)

O

Gas Connection Inset

3-1/2” (89mm)

3-1/2” (89mm)

P

Gas Connection Width

4” (102mm)

4” (102mm)

G

H

I

K

J

L

O P

N

M

10" (254mm)

dia. Hole through

wall Vent.

Opening for gas

connection

Top Header

Drywall

(or other

facing)

*

If using the Barcelona Surround, Kensington, Balmoral, or

Tripoli Screen Door please note that framing and facing must
be non combustible (12” on top and 6” on both sides) and that
the Barcelona is only approved for installation with a single
sidewall.

P36 - P36D Gas Fireplace

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

Rigid Pipe Vent Systems:

Simpson Dura-Vent® Direct Vent GS
American Metal Products Ameri Vent
Security Secure Vent®
Selkirk Direct-Temp.

***

Important: Framing height requires consideration of the hearth

depth. Dimension H = H + the thickness of installed hearth.

Please refer to Page 11 (Exterior Vent Terminations)

for additional guidelines on vent locations.