Tank access and replacing parts

con’t.

Task

Operation

Replace Thermistor Steam Sensor

1. Directions as above in Cover Removal.

2. Remove PCB cover plate.

3. Remove the thermistor.

4. The probe end of the thermistor pushes into the

condensor tube so that the tip just covers the hole
drilled in the condensor tube.

5. Re-connect the sensor to the PCB at either NTC 1 or

NTC 2, in any order.

Redring SB

Condensor Tube

Sensor Probe