RIDGID K-2000 User Manual

Page 8

Advertising
background image

K-2000 Municipal Sewer Cleaning Machine

Ridge Tool Company • Elyria, Ohio • U.S.A.

6

Figure 5 – Cable Operation

Starting Engine/Generator

CAUTION

Make sure engine crankcase is filled to indicated
level with SAE-30 Oil.

1. Fill tank with regular gasoline.

2. Open gas shut-off valve.

3. Position FOR/OFF/REV SWITCH in OFF position.

4. Put ON/OFF SWITCH to ON position and close

choke.

5. Pull starter rope. Engine should be running after two

or three pulls.

6. Open choke when engine catches. Warm up engine

for three minutes.

NOTE! For any reason engine does not start, refer to

power plant instruction manual in tool box.

Operating Machine Using Cables

1. Place FOR/OFF/REV SWITCH (Figure 3) in FOR

position.

2. Push on clutch handle maintaining firm pressure

while feeding cable.

3. If tool meets heavy obstruction, release clutch handle,

and place switch handle in OFF position.

4. When cable rotation stops, place switch handle in

REV position and push firmly on clutch handle to
back out and release tool.

5. When tool is free, place switch handle in OFF then

FOR position to advance cable.

NOTE! Heavy and stubborn obstructions will require sev-

eral repetitions of this procedure.

6. Release clutch handle and connect additional cables

from rear as required.

7. As additional cables are added, keep count by ad-

vancing manual cable counter.

Rear Guide

Hose

Turnbuckle

Manhole

Guide Pipe

Figure 6 – K-2000 Machine with Rod Driver Assembly and Clutch Handle in Remote Control Housing

Tool Box

Engine/Generator

Fuel

Tank

Rear Wheel

Lock

Pull Starter

Latch

Guard

Control Panel

Motor Table

Rod Driver

Assembly

FOR/OFF/REV

Switch

Propulsion

Clutch Handle

Clutch

Handle

Rod Driver

Nose Cone

Spring

Loaded Pin

Advertising