Raypak 2100 - 4001 EN User Manual

Raytherm, Type h, Hydronic heating boilers commercial

Advertising
background image

Catalog No.: 2000.26M

Effective: 12-1-07

Replaces: 12-1-99

Job:

Engineer:

Contractor:

Prepared By:

Model

:

Date:

EFFICIENT
 82% thermal efficiency – highest of any atmospheric

boiler available today

THERMAL SHOCK PROOF
 Twenty-year warranty against thermal shock damage

up to 150°F differential

 Maximum operating temperature: 230°F

LIGHTWEIGHT
 A floor load of 70 lbs./sq. ft. or less

HIGH RECOVERY
 Cuts fuel costs substantially because the standby and

radiation losses normal to other boilers and tank-type
water heaters are eliminated

LOW WATER OPERATING TEMPERATURE
 Operates with water temperature as low as 105°F

without condensing

Heat Exchanger
ƒ ASME Inspected and Stamped

160 PSIG

ƒ National Board Approved
ƒ Headers

Glass-lined Cast Iron – Standard
Bronze – Option A-1

ƒ Finned

Tubing

Copper – Standard
Cupro Nickel – Option A-3

ƒ ASME Steel Tube Sheet
ƒ Silicone

O-Rings

ƒ 60 PSIG ASME Pressure Relief Valve
ƒ Temperature and Pressure Gauge

(Boiler)

ƒ Water

Connections

Left Hand – Standard
Right Hand – Option A-6

ƒ Flow

Configuration

Two-pass (Standard)
Single-pass (Cast Iron Only)

Controls
ƒ 120V, 60Hz, 1 Ph Power Supply
ƒ 120/24V

Transformer

ƒ 100% Pilot Shut-off/Lockout
ƒ Electronic, Intermittent Ignition (IID)

Pilot

ƒ High Limit Control, Manual Reset
ƒ High Limit Control, Auto Reset –

Models 3001-4001

ƒ On/Off

Switch

ƒ Flow

Switch

ƒ Economaster II Pump Time Delay

Gas Control Train
ƒ Manual Main Gas Shut-off Cock
ƒ Main Gas Pressure Regulator
ƒ Redundant Safety Shut-off Valve
ƒ Control Valve
ƒ Firing

Mode

On/off (H4)
Two-stage Firing (H3)
Four-stage Firing (H9)
Motorized Modulation (H2)
B-6000 (H6)

ƒ Fuel

Natural Gas
Propane Gas

ƒ Design Certified ANSI Z21.13/

CSA 4.9

Construction
ƒ Front

Controls

ƒ Stainless Steel Burners
ƒ Polytuf Powder Coat Finish
ƒ Built-in Draft Diverter
ƒ Draft

Inducer

Motorized Draft Inducer –

Option D-2


Temperature Controllers

B-7

Modulating

B-5

Modulating, Outdoor Reset

B-6

Two-stage

B- Four-stage Digital
Y-241 Electronic Sequencer,

1-4 Stages

Y-281 Electronic Sequencer,

1-8 Stages

Additional Safety Controls

F-9

Low Water Cut-off Probe

I-1

High Limit Control,
Auto Reset

S-1

Low Gas Pressure Switch

S-2

High Gas Pressure Switch

Regulatory Agency Requirements

Raytherm

®

- Type H

Hydronic Heating Boilers

Commercial

Models 2100-4001 (Indoor)

Fig. 8184

Advertising