Safety Devices













Venting

Maximum Vent Length

Wall Thickness and
Flue Manifold Kits
(the “A” vent kit is included
with the appliance)




Warranty

• Flame rod detects flame failure; results in auto shutdown to prevent escape

of gas

• Bi-metal switch, thermal fuse, and thermistor detect overheat condition;

results in auto shutdown

• 3 amp fuse protects against power surge; results in auto shutdown
• Abnormal spark at time of ignition results in auto shutdown
• Combustion fan purges any gas from the combustion chamber before

ignition

• Convection fan continues to run after burner shutdown to cool internal parts
• Function lock prevents inadvertent operation
• Appliance shuts down if room reaches 104° F (40° C)

concentric; 3 1/8 inch (80 mm) wall hole

13 feet (4 m) with a maximum of 2 bends; maximum 8 feet (2.4 m) vertically

Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years with years 6-10
prorated

DIMENSIONS

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.

Name

Kit No.

fits walls

S Vent Kit

FOT-150

3 - 4 1/2 in (75 - 115 mm)

A Vent Kit

FOT-151

4 1/2 - 9 1/2 in (115 - 240 mm)

B Vent Kit

FOT-152

9 1/2 - 15 3/4 in (240 - 400mm)

C Vent Kit

FOT-153

15 3/4 - 23 5/8 in (400 - 600 mm)

D Vent Kit

FOT-154

23 5/8 - 31 1/2 in (600 - 800 mm)