ELECTRICAL

DOUBLE INSULATION

Double insulation is a concept in safety in electric power
tools, which eliminates the need for the usual three-wire
grounded power cord. All exposed metal parts are
isolated from the internal metal motor components with
protecting insulation. Double insulated tools do not need
to be grounded.

Important: Servicing of a tool with double insulation
requires extreme care and knowledge of the system and
should be performed only by a qualified service
technician. For service, we suggest you return the tool to
your nearest authorized service center for repair. When
servicing, use only identical Ryobi replacement parts.

WARNING:

The double insulated system is intended to protect the
user from shock resulting from a break in the tool's
internal wiring. Observe all normal safety precautions
related to avoiding electrical shock.

ELECTRICAL CONNECTION

The router has a precision built electric motor. It should
be connected to a power supply that is 120 volts, 60 Hz,
AC only (normal household current). Do not operate this
tool on direct current (DC). A substantial voltage drop will
cause a loss of power and the motor will overheat. If your
tool does not operate when plugged into an outlet,
double-check the power supply.

EXTENSION CORDS

When using a power tool at a considerable distance from
a power source, be sure to use an extension cord that
has the capacity to handle the current the tool will draw.
An undersized cord will cause a drop in line voltage,
resulting in overheating and loss of power. Use the chart
to determine the minimum wire size required in an
extension cord. Only round jacketed cords listed by
Underwriter’s Laboratories (UL) should be used.

When working outdoors with a tool, use an extension cord
that is designed for outside use. This type of cord is
designated with “WA” on the cord’s jacket.

Before using any extension cord, inspect it for loose or
exposed wires and cut or worn insulation.

**Ampere rating (on tool faceplaate)

0-2.0

2.1-3.4

3.5-5.0

5.1-7.0

7.1-12.0

12.1-16.0

Cord Length

Wire Size (A.W.G.)

25'

16

16

16

16

14

14

50'

16

16

16

14

14

12

100'

16

16

14

12

10

**Used on 12 gauge - 20 amp circuit.

WARNING:

Keep the extension cord clear of the working area. Posi-
tion the cord so that it will not get caught on lumber, tools
or other obstructions while you are working with a power
tool. Failure to do so can result in serious personal injury.

WARNING:

Check extension cords before each use. If damaged re-
place immediately. Never use tool with a damaged cord
since touching the damaged area could cause electrical
shock resulting in serious injury.