Always remember:
Battery water and water containing additives (such as starch,
perfume or fabric conditioner) may not be used. Such
additives can affect the properties of the steam and, at high
temperatures, can form deposits in the steam chamber, which
will mark the laundry when they are emitted through the
steam vents. Descaling liquids/agents should not be used.

TROUBLESHOOTING

Issues

Possible causes

Solutions

Water runs

Boiler is too full.

Do not fill the boiler

through the

with more than 33oz

holes in the

water.

soleplate.

Thermostat isn't

Send appliance to an

working.

authorized service

center.

The iron was used

Wait for the tempe-

before it had reached

rature/steam control

temperatures.

lights to go out
before ironing.

Water has condensed

Press the steam

in the steam tube as

control button away

iron hasn't been used

from your clothes

for some time.

until iron produces

steam.

DG 580

DG 580

Steam output control

Decrease steam out-

dial is set too high

put while ironing at

for the temperature

low temperature (

).

set on the iron.

White streaks The boiler has a build- Rinse the boiler after

come through up of scale and needs

every 10 uses (see

the holes in

to be rinsed out

Cleaning and Main-

the soleplate. regularly.

tenance section).

Brown streaks Chemical descaling

Never use descaling

come through agents or additives

agents or additives.

the holes in

have been used.

Rinse boiler

the soleplate.

thoroughly.

Tap water is high in

Switch to bottled

organic matter such

spring water or rinse

as rust or iron.

boiler more often.

The soleplate Ironing at too high a

Refer to the Steam

has build-up. temperature.

Ironing section of the
instructions for
temperature

recommendations.

Spray starch

Spray starch on the

build-up.

reverse side of the

garment.

There is little The boiler is empty.

Fill the boiler.

or no steam.

The boiler is not

Wait for the steam

ready.

indicator light to go

out before using
steam.

Steam escapes Cap screwed on

Unscrew cap when

from the

incorrectly.

unit is cold and put

boiler cap.

back on.

The seal on the cap

Check cap regularly

is worn.

for signs of wear and

tear to red rubber
ring. Replace if wear
is noticed.

If troubleshooting does not assist, before consulting the
retailer regarding their return/exchange policy, please
telephone consumer service at 781-396-0600.

Advertising