Part two installation and service instruction – Raypak P-R185B To P-R405B User Manual

Page 10

Advertising
background image

SECTION 1 - RECEIVING EQUIPMENT

On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton
is damaged, a note should be made on the Bill of Lading when signing for equipment. Remove the heater from the
carton and if it is damaged, report the damage to the carrier immediately. Save the carton.

These items are shipped loose inside the carton with the heater:

STANDARD UNIT

ASME UNIT

1. "Pagoda" Top

1. "Pagoda" Top

2. 2" CPVC Union with "O" rings (2)

2. In/Out Flanges (2)

3. Plastic pipe finish flange for gas line

3. 1-1/2" Flange Gaskets (2)

4. Bonding lug with mounting screw

4. 2" Flange Gaskets (2)

(IID units only)

5. Flange Bolts (4)
6. Pressure Relief Valve
7. 2" CPVC Adapters (2)
8. Plastic pipe finish flange for gas line.
9. Bonding lug with mounting screw. (IID units only).

Be sure that you receive the number of packages indicated on the Bill of Lading.

When ordering parts, you must specify model and serial number of heater. When ordering under warranty conditions,
you must also specify date of installation. Raypak recommends that this manual be reviewed thoroughly before
installing your Raypak pool/spa heater. If there are any questions that this manual does not answer, please contact
the factory or your local Raypak representative.

SECTION 2 - GENERAL SPECIFICATIONS

These heaters are design certified and tested under the requirements of ANSI Z21.56 / CSA 4.7 American National
Standard / CSA Standard for Gas-Fired Pool Heaters. All heaters are inter-changeable and can be used either indoor
or outdoors. The appropriate top designated for that type of use is required. If desired, the top can be changed at
a later date to change from outdoor to indoor or vice versa. Millivolt heater contains a self-generating electrical system
operating between .25 and .75 volts.

Ambient Temperature Rating of Heater Components
Millivolt Heater with Honeywell Gas Valve +32°F to +175°F
Millivolt Heater with Robertshaw Gas Valve 0°F to +175°F
Electronic Ignition Heaters* -32°F to + 175°F
*Requires 120V or 240V Power Supply

Atmospheric heaters:
Rated inputs suitable for up to 2000 feet elevation. For elevations above 2000 feet, reduce input 4% for each 1000
feet above sea level, as high elevation reduces combustion performance.
Low NOx heaters:
Rated inputs suitable for up to 5000 feet elevation. For elevations above 5000 feet, consult the factory.

10

PART TWO
INSTALLATION AND SERVICE INSTRUCTION

Advertising
This manual is related to the following products: