Raypak Raytherm - Type WH 962-1826 User Manual

Raytherm, Type wh, Water heaters commercial

Advertising
background image

Catalog No.: 3500.23D

Effective: 1-15-08

Replaces: 7-15-04

Job:

Engineer:

Contractor:

Prepared By:

Date:

Model:

EFFICIENT
 82% thermal efficiency – highest of any atmospheric

water heater available today

THERMAL SHOCK PROOF
 Twenty-year warranty against thermal shock damage

up to 150°F differential

 Maximum operating temperature: 210°F

LIGHTWEIGHT
 A floor load of 70 lbs./sq. ft. or less

HIGH RECOVERY
 Cuts fuel costs substantially because the standby and

radiation losses associated with tank-type
water heaters are eliminated

LOW WATER OPERATING TEMPERATURE
 Operates with water temperature as low as 105°F

without condensing

Heat Exchanger
ƒ ASME Inspected and Stamped

160 PSIG

ƒ National Board Approved
ƒ Headers

Bronze – Standard
Glass-lined Cast Iron – Option A-2

ƒ Fin

Tubing

Copper – Standard
Cupro Nickel – Option A-3

ƒ ASME Steel Tube Sheet
ƒ Silicone

O-Rings

ƒ 125 PSIG ASME Pressure Relief Valve
ƒ Temperature and Pressure Gauge
ƒ Water

Connections

Left Hand – Standard
Right Hand – Option A-6

ƒ Two-pass Flow Configuration
ƒ Pump, Rear-mounted, 1/2 HP,

120 VAC, 1

∅, 60 Hz – Optional

4.25” Impeller
4.7” Impeller

Controls
ƒ 120V, 60Hz, 1 Ph Power Supply
ƒ 120/24V

Transformer

ƒ 100% Pilot Shut-off/Lockout
ƒ Electronic, Intermittent Ignition (IID)

Pilot

Controls (cont.)
ƒ High Limit Control, Manual Reset –

200°F

ƒ On/Off

Switch

ƒ Flow

Switch

ƒ Economaster II Pump Time Delay

Gas Control Train
ƒ Manual Main Gas Shut-off Cock
ƒ Main Gas Pressure Regulator
ƒ Redundant Safety Shut-off Valve
ƒ Control Valve
ƒ Firing

Mode

On/Off
2-stage Firing
Mechanical Modulation

ƒ Fuel

Natural Gas
Propane Gas

ƒ Design Certified ANSI Z21.10.3

Construction
ƒ Front

Controls

ƒ Stainless Steel Burners
ƒ PolyTuf Powder Coat Finish
ƒ Vent

Selection

Drafthood – Option D-10
Motorized Draft Inducer –

Option D-2

ƒ Base – Optional

Combustible Floor Shield –

Option J-1


Temperature Controls

B-2

Single-Stage Tankstat
(100-180°F)

B-3

2-Stage Tankstat (100-180°F)

Y-241 Electronic Sequencer,

1-4 Stages

Y-281 Electronic Sequencer,

1-8 Stages

Additional Safety Controls

F-9

Low Water Cut-off Probe

I-3

High Limit Control, Auto
Reset, 180°F

S-1

Low Gas Pressure Switch,
Manual

S-2

High Gas Pressure Switch,
Manual

Regulatory Agency Requirements

CSD-1

Safety

Controls

INDOOR

Raytherm

®

- Type WH

Water Heaters

Commercial

Models 962-1826 (Indoor)

Advertising