EPR Proprietary I Licensed Material

Rolls-Royce Aero-Derivative Combustion Turbine Background

2-13

Design

Characteristic

RB211 – 6562

(RB211-24G Gas Generator

with RT62 Power Turbine)

RB211 – 6761

(RB211-24GT Gas

Generator with RT61 Power

Turbine)

Trent 60 DLE

(Derivative of AERO 800 on

Boeing 777 and Airbus

A330)

Trent 60 WLE

(Derivative of AERO 800 on

Boeing 777 and Airbus

A330)

Reliability, Maintainability, Durability

Comments

Starting Means

Hydraulic Starter via radial

drive gearbox on HPC

Hydraulic Starter via radial

drive gearbox on HPC

Hydraulic Starter

(250 kW motor)

Hydraulic Starter

(250 kW motor)

Compressor

Variable Stages

1 stage of 34 VIGV's

1 stage Solid Variable Inlet

Guide Vane (VIGV)

Revised VIGV Control

RVDT (Rotary Variable Diff.

Transformer)

IGVs in Front of the LPC

IPC has Stage 1 VIGV's
IPC has 2 rows of VSVs

HPC has no variable stators

IGVs in Front of the LPC

IPC has Stage 1 VIGV's
IPC has 2 rows of VSVs

HPC has no variable stators

Compressor

Blades

LPC Titanium Blades coated

with Sermetel "W"; HPC

Blades Stage 1 Ti, Stg 2-6

Stainless Steel

LPC Blades-Titanium

IPC Blades-Titanium

HPC Blades 1,2 - Titanium

HPC Blades 3,4,5 - Nimonic

LPC Blades-Titanium

IPC Blades-Titanium

HPC Blades 1,2 - Titanium

HPC Blades 3,4,5 - Nimonic

Compressor

Vanes

First stage (34) VIGV's,

Stages 2 thru 7 fixed on IP

Compressor. 6 fixed stages

of stators in the HP

Compressor

Redesigned Stage 5 stator,

Hard-faced stage 6 stator,

First stage (34) VIGV's,

Stages 2 thru 7 fixed on IP

Compressor. 6 fixed stages

of stators in the HP

Compressor Revised OGV

ring ( Stage 7) fitted to IP

Compressor.

LP - 1 variable 2 fixed

IP 2 Variable 7 fixed HP 8

fixed

LP - 1 variable 2 fixed

IP 2 Variable 7 fixed HP 8

fixed

Compressor

Rotor

IPC Welded Drum SS & Ti

HPC Welded Drum Ti

Trent 800 HPC Compressor

LPC Operates at 3600 or

3000 RPM without the need

for a reduction gear. The

LPC blades are changed for

50 Hz Operation.

LP - 2 Stage IP - 8 Stage

HP - 6 stages

LPC Operates at 3600 or

3000 RPM without the need

for a reduction gear. The

LPC blades are changed for

50 Hz Operation.

LP - 2 Stage IP - 8 Stage

HP - 6 stages

Compressor

Casings

Air Intake Al Alloy Casting

IPC Casing Al Alloy Casting

HPC 12% Cr SS

Single Skin Inlet Bullet-nose

with the elimination of anti-

icing (-24G and -24GT)

LPC Outer Case is Split to

Access the LPC Stators

LPC Outer Case is Split to

Access the LPC Stators

Turbine Casings

Turbine Casing Nimonic PE.

16

Single Piece Frame Turbine

Support