Renesas M3T-ICC740 User Manual

Page 15

Advertising
background image

• Right click on the FlashLEDs(); function and

select ‘Go To Cursor’ as illustrated.

The code will execute to the selected line and stop. An automatic breakpoint was inserted in the code and then removed after calling the

break.

• Press ‘Step Over’ on the debug toolbar.

The code will run and flash the LEDs 200 times. The debugger will not exit until all 200 flashes have completed or a button is pressed on the

Renesas Starter Kit.

• To stop the LEDs flashing press the SW1 button on the Renesas Starter Kit to exit the FlashLEDs() function.

The code will run to the breakpoint we previously set on the TimerADC function, note that the yellow PC arrow will now be superimposed

on the breakpoint indicator, this confirms the breakpoint has been reached.

The TimerADC function initialises an interrupt on an available internal timer. On a compare match in the timer module, an interrupt is

generated. In the TimerADC code version the interrupt reads the last ADC conversion from the external potentiometer and uses the

result to set the next compare match value. The ADC conversion is then re-started.

The interrupt initialisation is completed as part of the hardware setup. This is contained in the file ‘interrupts.c’.

• Open the file ‘interrupts.c’ by double clicking on the file in the Workspace window.

• Review this file and find the interrupt function that changes the LED pins; Timer2_Handler(void).

• Set a breakpoint on the line where the LED pins are modified.

• Press <Go> or <F5> to run the code from the

current PC position.

The code will stop in the interrupt routine. It is now possible to step through the interrupt function.

• Remove the breakpoint in the interrupt by double clicking again before exiting the function.

• Press <Go>to run the code from the current PC

position.

The code will now run to the infinite loop at the end of Main. The user LEDs will now be flashing. You can modify the flashing rate by

adjusting the potentiometer on the Renesas Starter Kit.

• Press <Stop> on the debug toolbar.

11