Rikaline – Rikaline III User Manual

Page 18

Advertising
background image

GPS-6036 Operating Manual

Rikaline

Rikaline

International Corp.

14F, 171, Chen-Gong Road, SanChong City, Taipei 241, Taiwan

Tel: ++886 2 8973 1899 Fax: ++886 2 8973 1896 E-Mail:

[email protected]

Web: www.rikaline.com.tw

18

Capacity

cut-off within 1 hour after complete charge.

3 Cycle

Life

Measure the capacity after 300 cycles of complete charge
and discharge at 1C current to 2.75V cut-off

80% of initial Capacity

Capacity after 30days storage at 25 from complete
charge

Retention capacity 90%

4 Storage

Capacity after 7days storage at 60 ffom complete charge Recovery capacity 90%

C.3.2.2 Environmental Characteristic

NO ITEM

TESTING

INSTRUCTION

REQUIREMENTS

1

Temperature

testing

Measure capacity with constant discharge current 1C to 2.75V
cut-off at each temperature after complete charge at 25 .
Percentage as an index of the capacity compared with
100% at 25 .

25% at -20
60% at 0
100% at 25
96% at 60

2

Constant

temperature

/humidity

Keep the battery at 40 and 90%RH for 96hrs Recovery

capacity 85%

3 Vibration

The battery will be vibrated 10 times in three mutually
perpendicular directions with amplitude of 0.35mm and
changing frequency between 10 and 55Hz. The rate of
scanning frequency is from 10Hz to 55Hz with the rate of
1Hz per min.

4

Impacting

Testing

The battery will be impacted 1000±10 times with the
acceleration of 100m/s

2

and pulse lasting time 16ms.

5 Free

fall

The battery will be dropped free five times in three mutually
perpendicular directions from the height of 1.0m onto a
hard board with the thickness of 20mm

The battery shall not
rupture, smoke, catch fire,
vent or leak.


C.3.2.3 Safe Characteristic

NO ITEM

TESTING

INSTRUCTION

REQUIREMENTS

1 Short

Circuit

The battery is to be short-circuited by connecting the
positive and negative terminals of the battery with an
external load of less than 50mΩ

2

Over charge

testing

According to the method of UL

3

Over

discharge

testing

After complete charge, the battery will be discharged to end
voltage. Then Connect with external load of 30Ω for 24hrs.

The battery shall not
rupture, smoke, catch fire,
vent or leak.

C.3.3 Cautions

1) The best operating performance is between -20 ~ +60 °C. Higher or lower temperature could cause
damage to the battery.
2) Operated with external power supply will not hurt battery life since battery does not discharge. Therefore, it
operating temperature range is -40 ~ +85°C.
3) Recharge the battery for 10 hours before use.