DISPLAY: 5 digit LCD 0.48" (12.2 mm) high digits

DP63000A-I: Reflective LCD with full viewing angle
DP63000B-I: Transmissive LCD with selectable red or green LED backlight,
viewing angle optimized. Display color change capability with output state
when using an output module.

2. POWER: Input voltage range is +9 to +28 VDC with short circuit and input

polarity protection. Must use a DP6-MLPS1 or a Class 2 or SELV rated power
supply.

3. INPUT RANGES: Jumper Selectable

D.C. Currents: 200

µA, 2 mA, 20 mA, or 200 mA

4. SIGNAL INPUTS:

5. OVERRANGE RATINGS, PROTECTION & INDICATION:

9 to 28 VDC power circuit is not isolated from the signal circuit.
Input Overrange Indication: “

OLOL

”.

Input Underrange Indication: “

ULUL

”.

Display Overrange/Underrange Indication: “

.....

”/“-

.....

6. DISPLAY RESPONSE TIME: 500 msec min.
7. NORMAL MODE REJECTION: 60 dB 50/60 Hz
8. USER INPUT (USR): Programmable input. Connect terminal to common

(USR COMM) to activate function. Internal 10K

Ω pull-up resistor to +9 to

28 VDC.
Threshold Levels: V

IL

= 1.0 V max; V

IH

= 2.4 V min; V

MAX

= 28 VDC

Response Time: 5 msec typ.; 50 msec debounce (activation and release)

9. MEMORY: Nonvolatile E

2

PROM memory retains all programming

parameters and max/min values when power is removed.

10. ENVIRONMENTAL CONDITIONS:

Operating Temperature Range for DP63000A-I: -35 to 75°C
Operating Temperature Range for DP63000B-I depends on display color

and intensity level as per below:

Storage Temperature: -35 to 85°C
Operating and Storage Humidity: 0 to 85% max. relative humidity (non-

condensing)

Vibration According to IEC 68-2-6: 5 to 500 Hz, in X, Y, Z direction for 1.5

hours, 5 g’s.

Shock According to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions
Altitude: Up to 2000 meters

11. CONNECTIONS: Wire clamping screw terminals

Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 5 inch-lbs (0.565 N-m) max.

12. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 requirements for

indoor use. Installation Category I, Pollution Degree 2. High impact plastic
case with clear viewing window. Panel gasket and mounting clip included.

13. CERTIFICATIONS AND COMPLIANCES:

SAFETY
UL Recognized Component, File #E313607, UL61010A-1, CSA 22.2 No. 61010-1

Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.

UL Listed, File # E313547, UL508, CSA C22.2 No. 14-M95

LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment

for measurement, control, and laboratory use, Part 1.

IP65 Enclosure rating (Face only), IEC 529
Type 4X Indoor Enclosure rating (Face only), UL50

ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for Measurement,

Control and Laboratory use.

Notes:
1. Criterion A: Normal operation within specified limits.

14. WEIGHT: 3.2 oz (100 g)

4

G

ENERAL

M

ETER

S

PECIFICATIONS

MODEL

NO.

DISPLAY COLOR

INPUT CURRENT

@ 9 VDC WITH

DP6-RLY0

DP63000A-I

---

10 mA

40 mA

DP63000B-I

Red (max intensity)

85 mA

115 mA

DP63000B-I

Green (max intensity)

95 mA

125 mA

TEMPERATURE

1 & 2

-35 to 75°C

3

-35 to 70°C

4

-35 to 60°C

5

-35 to 50°C

1 & 2

-35 to 75°C

3

-35 to 65°C

5

4

-35 to 35°C

-35 to 50°C

INTENSITY LEVEL

Class A

EN 55011

Emissions

Emissions:

30 A/m

3 V/rms
Criterion A

Criterion A

EN 61000-4-8

EN 61000-4-6

RF conducted interference

1 kV L-L,

Criterion A

EN 61000-4-5

Surge

1 kV signal

2 kV power

Criterion A

EN 61000-4-4

Fast transients (burst)

2 kV L&N-E power

10 V/m

Criterion A

EN 61000-4-3

Electromagnetic RF fields

8 kV air discharge

4 kV contact discharge

Criterion A

EN 61000-4-2

Electrostatic discharge

Immunity to Industrial Locations:

Power frequency magnetic fields

Green Display

Red Display

INPUT CURRENT

@ 9 VDC WITHOUT

DP6-RLY0

INPUT

RANGE

ACCURACY

@23 °C, less

than 85% RH

INPUT

IMPEDANCE

MAX

INPUT

SIGNAL

RESOLUTION

TEMP.

COEFFICIENT

200

µ

A

0.1% of span

1.111 K

15 mA

10 nA

70 ppm / °C

2 mA

0.1% of span

50 mA

.1 µA

70 ppm / °C

20 mA

0.1% of span

11

150 mA

1 µA

70 ppm / °C

200 mA 0.1% of span

1

500 mA

10 µA

70 ppm / °C

111

P

ART

N

UMBER

I

NFORMATION

DP6-SNK0

Dual Sinking Open Collector Output card

DP6-SOFT

DP6-485-CABLE

RS485 Programming Cable (DB9-RJ11)

DP63000B-I

PC Configuration Software for Windows 98, ME, 2000, XP

*

DC Current Meter with backlight display

DP6-232-CABLE

DP6-RLY0

DP6-MLPS1

Micro-Line Power Supply, 85 to 250 VAC

Single Relay Output Card

RS232 Programming Cable (DB9-RJ11)

DP6-COM2

RS232 Serial Communications Card

DP6-COM1

RS485 Serial Communications Card