OPTI-UPS PS1500C User Manual

Front panel rear panel

Advertising
background image

26.

Specifications

PS1000C / PS1250C / PS1500C / PS2000C / PS3000C

* PS1000C / PS1250C /

PS1500C / PS2000C /

PS3000C

windows

2000 / XP

2003 / Vista

Front Panel

Rear Panel

PS1000C / PS1250C / PS1500C /

PS2000C / PS3000C

PS1000C / PS1250C / PS1500C / PS2000C

Load

Buck AVR
Line Normal

Boost AVR

On / Test

OFF

Battery

Capacity

Overload

Backup

Replace

Battery

USB

TEL / Modem

Output

AC Input

RS232

SNMP

Port
Battery Pack
Input

Circuit

Breaker

USB

TEL / Modem

Output

AC Input

RS232

SNMP

Port

Battery Pack
Input

Circuit

Breaker

RS232

TEL / Modem

SNMP

Port
Output

Input

Circuit

Breaker

USB

Battery

Pack

PS3000C

Sine Wave

Line Interactive

UPS Series

On Line UPS

Series

A

VR Series

Networking

Series

Inverter Series

Surge Series

Green Power

Series

Standby UPS

Series

PS1000C PS1250C PS1500C PS2000C PS3000C

100 / 110 / 120 Vac or 220 / 230 / 240 Vac +/-25% (PS3000C 220V/230V/240V only)

50 or 60Hz +/-5% (auto sensing)

Pure Sine wave output at nominal +/-5%

50 or 60Hz +/-0.5%

3,500 meters max. elevation, 0%-95% humidity non-condensing, Temperature: 0-40ºC

<45dBA (1 meter from surface)

15,000 meters max. elevation

1000VA/600W 1250VA/750W 1500VA/900W 2000VA/1200W

3000VA/1800W

30 min.

35 min. 40 min.

45 min. 90 min.

Line-Interactive
Pure Sine Wave

(in)

(mm)

Dimension (Physical/ Packing)
(L x W x H)

35.0/36.1 33.1/36.2 33.1/36.2 62.6/66.1
13.9/15.3 15.0/16.4 15.0/16.4

28.4/30.3

14.9 x 5.5 x 7.9 / 19.2 x 10.6 x 12.8

378 x 140 x 201 / 487 x 270 x 326

17.7 x 6.7 x 8.9 / 22.0 x 11.8x 14.2

450 x 170 x 226 / 560 x 300 x 360

12V / 7.2AH x 2

12V / 34W x 2

12V / 34W x 4

AVR automatically increases output voltage 15% above input voltage when input voltage

drops lower than 9% from nominal. AVR decreases output voltage 13% below input voltage

when input voltage rises higher than 9% from nominal.

Typology
On-battery Output Wave Form
INPUT
Capacity
Voltage
Frequency
OUTPUT
Voltage (on battery)
Frequency (on battery)

Voltage Regulation AVR

PROTECTION & FILTERING
Spike Protection
Unit Input
EMI/RFI filter
Overload protection

Transfer Time
Short Circuit
BATTERY
Type
User Replaceable Battery
Typical Recharge Time
Protection

Back-up Time

(one PC and one 17” LCD monitor)

ALARM
Battery Back-Up
Battery Low
Overload
INTERFACE
RS-232 Interface
USB
Dry Contact
SNMP Slot
ENVIRONMENT
Ambient Operation
Audible noise
Storage condition
PHYSICAL
Weight (Net/Gross) (lbs)
(Kg)

420 Joules (IEC models) / 225 Joules (NEMA models), 8/20μs

Circuit breaker protection

10dB at 0.15MHz, 50dB at 30MHz

UPS automatic shutdown if overload exceeds 110% of nominal

for 20 second and 125% for 2 seconds

6~8 milliseconds (typical), including detection time

UPS output cut off immediately or input circuit breaker protection

Hot swappable, Sealed, Maintenance-free lead acid

4 hours (to 90% of full capacity)

Automatic self-test & discharge protection,

“Replace battery” indicator

Slow beeping sound (about 0.25Hz)
Rapid beeping sound (about 1.00Hz)

Continuous beeping sound

Yes

Yes

Sends AC fail and battery low singals, and receives shutdown signal from computer

Yes

Advertising
This manual is related to the following products: