Omnitron Systems Technology E1 User Manual

Omnitron Systems Technology Hardware

Advertising
background image

User Warranty Registration

Please register on-line

@ http://www.omnitron-systems.com

or complete both sides

and mail or fax this registration form to:

Omnitron Systems T

echnology

, Inc.

140 T

echnology Drive, #500

Irvine, CA 92618, USA

Fax: (949) 250-6514

Name:

_________________________________________________

Company:

______________________________________________

Address:

______________________________________________

______________________________________________

City: ___________________ State: _______

Zip Code:

________

Country:

_______________________________________________

Phone: ____________________

Fax:

_______________________

E-mail:

_________________________________________________

Please complete both sides of this form

FlexPoint

TM

T1/E1 Copper to Fiber
Converters

User Instructions

Description:

The FlexPoint T1/E1 connects T1 and E1 devices, such as
PBXs, CSUs and routers, via multimode (MM) or single-mode
(SM) fiber. Designed to extend the standard T1/E1 twisted pair
or Coax network distances over fiber, this converter provides
protection from environmental noise and effectively increases
high-speed network reliability. The following models are
described here.

Model #

Fiber Type

Max Distance

4470/90-x

MM, SC, 1310nm

5km

4471/91-x

SM, SC, 1310nm

30km

4472/92-x

MM, ST, 1310nm

5km

4473/93-x

SM, ST, 1310nm

30km

4474/94-x

SM, SC, 1310nm, LH

60km

Power Options (-x):
-0 No power adapter included (chassis module)
-1 110 Volt / 60 Hz
-2 110-230 Volt / 50 Hz

Mounting Options

4380

FlexPoint Wall-Mounting Hardware Kit

4384

FlexPoint 18 to 72VDC Stand-Alone Power Supply

4381

FlexPoint DC Converter Wall-Mounting Kit (for 4384)

4385

FlexPoint 14-Unit 48VDC Power-Redundant Chassis

4392

FlexPoint 5-Unit Rack-Mounting Shelf

4395

FlexPoint 14-Unit AC Power-Redundant Chassis

Power Adapter Notice

1. When Using in a stand-alone configuration, this product

is intended to be and must be used only with a Listed
Direct Plug-In Power Unit marked “Class 2” and rated
at 9VDC, 1 Amp.

2. This product should always be used only with Omnitron

Supplied Power Unit model numbers 9113-PS or 9115-PS.

WARNING!

Before inserting the Power Adapter, verify that the

power on the unit is appropriate for your AC line

voltage source.

Mounting instructions:

The FlexPoint Fiber Converter can be solo-mounted using
a wall-mounting kit, or rack-mounted using a 5-unit shelf,
or a high-density FlexPoint 14-Unit Power-Redundant
Chassis.

Fiber Optic Cable Attachment:

Connect the fiber cables between the FlexPoint T1/E1
converters. The transmit (Tx) must attach to the receive
side and the receive (Rx) must attach to the transmit side.
Note: Use fiber cables that are compliant with the
specifications that are outlined in fiber cable specifications.

Copper Cable Attachment:
RJ-45/RJ-48 T1/E1 connector

Connect to the RJ-45/48 connector on the FlexPoint T1/
E1 converter via a category 3 or better cable (Category
5 is recomended) and attach the other end to the network

equipment. (The twisted pair connection requires two active
pairs in a T1/E1 environment. The active pairs are pins
1&2 and pins 4&5. Only dedicated wire pairs should be
used for the active pins.) Set the UTP DCE / DTE switch
for the RJ-45/48 port to the appropriate setting.
Note: Use copper cables that are compliant with the
specifications that are outlined in copper cable specifications.

Coax E1 Connector

Attach the BNC to the FlexPoint T1/E1 converter and attach
the other end of the BNC to the network equipment.
Note: Use copper cables that are compliant with the
specifications that are outlined in copper cable specifications.

Switch Settings:
UTP DCE/DTE setting

The UTP DCE/DTE switch is used to eliminate the need for
crossover and custom cables to connect devices together when
using the RJ-45/48 port. Set this switch to DCE to use a
straight-through cable and to DTE when a crossover-cable
would be required.

T1/E1 Copper line configuration settings

The T1/E1 copper line codes and line lengths are configured
using dip switches located on the side of the FlexPoint T1/E1
media converter.

Line Type

Port Type

Distances

Switch Positions
1

2

3

4

T1 DSX-1

RJ-45/48

0’ - 133’

L

L

L

L

L L

L

L

L

L L

L

L

L

L L

L

L

L

L

T1 DSX-1

RJ-45/48

133’ - 266’

L

L

L

L

L L

L

L

L

L L

L

L

L

L K

K

K

K

K

T1 DSX-1

RJ-45/48

266’ - 399’

L

L

L

L

L L

L

L

L

L K

K

K

K

K L

L

L

L

L

T1 DSX-1

RJ-45/48

399’ - 533’

L

L

L

L

L L

L

L

L

L K

K

K

K

K K

K

K

K

K

T1 DSX-1

RJ-45/48

533’ - 655’

L

L

L

L

L K

K

K

K

K L

L

L

L

L L

L

L

L

L

T1 DS-1

RJ-45/48

0 dB

L

L

L

L

L L

L

L

L

L L

L

L

L

L L

L

L

L

L

T1 DS-1

RJ-45/48

-7.5 dB

L

L

L

L

L K

K

K

K

K L

L

L

L

L K

K

K

K

K

T1 DS-1

RJ-45/48

-15.0 dB

L

L

L

L

L K

K

K

K

K K

K

K

K

K L

L

L

L

L

T1 DS-1

RJ-45/48

-22.5 dB

L

L

L

L

L K

K

K

K

K K

K

K

K

K K

K

K

K

K

E1 75

Ω

Coax/BNC Standard

K

K

K

K

K L

L

L

L

L L

L

L

L

L L

L

L

L

L

E1 120

Ω

RJ-45/48

Standard

K

K

K

K

K L

L

L

L

L L

L

L

L

L K

K

K

K

K

E1 75

Ω

Coax/BNC Extended

K

K

K

K

K L

L

L

L

L K

K

K

K

K L

L

L

L

L

E1 120

Ω

RJ-45/48

Extended

K

K

K

K

K L

L

L

L

L K

K

K

K

K K

K

K

K

K

Operational switch settings and functions

The following operational switches located on the front of
the FlexPoint T1/E1 converter are to assist in installation
and fault isolation.

Local loop-back (L/LB)

This switch will set the FlexPoint T1/E1 converter in a
loop-back mode on both the fiber and copper connections.
By returning the switch to the normal position the unit will
resume to normal operation.

Remote loop-back (R+L/LB)

This switch will allow the entire fiber segment to be tested
at either of the FlexPoint T1/E1 converters without having
to set switches on both units. When set in this mode the
local unit is switched to a local loop-back mode. The fiber
Tx port will be further encoded to carry a remote loop-back
protocol. This remote loop-back will set the far end
FlexPoint T1/E1 converter to remote loop-back mode and
return a signal to the sending unit. An LED on the local
and remote FlexPoint T1/E1 converters will show a
confirmation that the fiber segment is communicating
properly between devices. By returning the switch to the
normal position it will return to normal operation.

DCE

Twisted
Pair #1

Twisted
Pair #2

RTIP

RRING

TTIP

TRING

RTIP

RRING

TTIP

TRING

1

2

4

5

DTE

Twisted
Pair #1

Twisted
Pair #2

RTIP

RRING

TTIP

TRING

RTIP

RRING

TTIP

TRING

1

2

4

5

Local Dual Loop Back
Remote & Local Loop Back
Force 1’s to Fiber
Force 1’s Copper

Normal

Cu-Rx

Cu-Tx

FO-Tx

FO-Rx

Loopback Enabled

Cu-Rx

Cu-Tx

FO-Tx

FO-Rx

FO-Rx

FO-Tx

Cu-Tx

Cu-Rx

Remote Loop Request

Over Fiber

Copper Cable Specifications:
Twisted-Pair cable for T1

Gauge

22 to 24 AWG

Impedance

100

Ω

+ 10%

Impedance characteristic

2.6 dB / 100m @ 1.0 MHz

Maximum distance

6,000 ft

Twisted-Pair cable for E1

Gauge

22 to 24 AWG

Impedance

120

Ω

+ 10%

Impedance characteristic

2.6 dB / 100m @ 1.0 MHz

Maximum distance

8,000 ft

Coax cable for E1

Gauge

22 to 24 AWG

Impedance

75

Ω

+ 10%

Impedance characteristic

2 dB / 100m @ 1.0 MHz

Maximum distance

8,000 ft

For product specifications refer to the product data sheet.

Technical Support:

For help with this product, contact our Tech. Support:
Phone:

(949) 250-6510

Fax:

(949) 250-6514

Address:

Omnitron Systems Technology, Inc.
140 Technology Drive, #500
Irvine, CA 92618 USA

E-mail:

[email protected]

URL:

http://www.omnitron-systems.com

Local loop-back and Remote loop-back

When both Local and Remote Loop-back are set to the
Normal position, the FlexPoint T1/E1 uses the default B8ZS
data format. When both switches are turned to their On
position, it uses the AMI data format.

Transmit/force 1’s to fiber

This switch is used to insert an “all ones” pattern into the
data stream being transmitted out of the fiber port on the
FlexPoint T1/E1 converter. Data being received on the coax
or twisted pair will be disabled and data being received on
the fiber is passed through to the coax or twisted pair side.
By returning the switch to the normal position the unit will
resume to normal operation.

Transmit/force 1’s to Coax or UTP

This switch is used to insert an “all ones” pattern into the
data stream being transmitted out of the coax or twisted
pair on the FlexPoint T1/E1 converter. Data being received
on the fiber will be disabled and data being received on
the coax or twisted pair is passed through to the fiber side.
By returning the switch to the normal position the unit will
resume to normal operation.

Alarm Relay Contacts

The FlexPoint T1/E1 features dry relay contacts for
optionally connecting the it into a separate T1/E1 alarm
circuit. The relay closes when a loss of power or when
signal detect is lost to the copper or fiber connection.

Operational rating on relay pins 3 & 6: 0-220VDC max 2A

LED Indicators

LED

Color

Status

Description

Power:

Yellow

On

Power applied

Fiber:

Green

Off

No signal detect

On

Signal detect

Blink

All ones received

UTP/Coax:

Green

Off

No signal detect

On

Signal detect

Blink

All ones received

Test:

Green

Off

Normal operation

On

L/LB or All 1’s Test mode

Blink

R+L/LB Received master

Fast Blink

R+L/LB Received slave

Fiber Cable Specifications:
Multimode

Cable:

50/125, 62.5/125, 100/140

μm

Wavelength:

1310nm

Max Distance:

5km

Singlemode

Cable:

9/125

μm

Wavelength:

1310nm

Max Distance:

30km

Singlemode long-haul

Cable:

9/125

μm

Wavelength:

1310nm

Max Distance:

60km

Warning

The operating description in this Instruction Manual is for use
by qualified personnel only. To avoid electrical shock, do not
perform any servicing of this unit other than that contained in
the operating instructions, unless you are qualified and certified
to do so by Omnitron Systems Technology, Inc.

Caution

All user-required operations can be performed without opening
the unit. Never attempt to open or remove the cover or tamper
with the unit.

Warranty

This product is warranted to the original purchaser against
defects in material and workmanship for a period of TWO
YEARS from the date of shipment. A LIFETIME warranty may
be obtained by the original purchaser by REGISTERING this
product with Omnitron within 90 days from the date of shipment.
TO REGISTER, COMPLETE AND MAIL OR FAX THE
REGISTRATION PORTION OF THIS INSTRUCTION
MANUAL TO THE INDICATED ADDRESS. Or you may
register your product on the Internet at http://www.omnitron-
systems.com. During the warranty period, Omnitron will, at its
option, repair or replace a product which is proven to be
defective.
For warranty service, the product must be sent to an Omnitron
designated facility, at Buyer’s expense. Omnitron will pay the
shipping charge to return the product to Buyer’s designated
US address using Omnitron’s standard shipping method.

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting
from improper or inadequate use and/or maintenance of the
equipment by Buyer, Buyer-supplied equipment, Buyer-supplied
interfacing, unauthorized modifications or tampering with
equipment (including removal of equipment cover by personnel
not specifically authorized and certified by Omnitron), or misuse,
or operating outside the environmental specification of the
product (including but not limited to voltage, ambient
temperature, radiation, unusual dust, etc.), or improper site
preparation or maintenance.

No other warranty is expressed or implied. Omnitron specifically
disclaims the implied warranties of merchantability and fitness
for any particular purpose.

Exclusive Remedies

The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for any direct,
indirect, special, incidental, or consequential damages, whether
based on contract, tort, or any legal theory.

Form: 040-04470-002D 11/07

Relay

3

6

RJ-45/RJ-48

User Warranty Registration

Please register on-line at

http://www.omnitron-systems.com

or complete both sides

and return this form to Omnitron Systems.

Model:

_________________________________________________

Serial Number: ______________

Purchase Date:

______________

Purchased From: _________________________________________

Address:

______________________________________________

City: ___________________ State: _______

Zip Code:

________

Country:

_______________________________________________

Comments and

Suggestions:

_______________________________

______________________________________________________

______________________________________________________

Please complete both sides of this form

Advertising
This manual is related to the following products:

T1