Applications (continued)

Application 1: Basic Small Network Connection.
• Power supplied to network from PC via network card, no PSIM used.
• Modules connected using standard communication cables.

Volt drop total in mV

=

cable 1 + module (3 off) + cable 2 + module (3 off)

=

(15.2 x 6) + 0.04(6+5+4+3+2+1) + (15.2 x 3) + 0.04(3+2+1)

=

138 mV

Then approximate voltage at end of network =

nominal supply voltage - calculated volt drop

= 5.1 - 0.138
= 4.96

V