Oregon Scientific IWA-80051 User Manual

Oregon Scientific Clock

Advertising
background image

CMOS: TM8727-XXX, LCD-478, BATTERY 2 x AAA

Model: C8191 AWB SIZE:A4 PANTONE: 445C

Weather Station With

Atomic Clock

Model IWA-80051

User’s Instructions

Please read these instructions carefully and store them

in a safe place for future reference.

FEATURES

• Multi-language calendar: English/German/

French/Spanish

• Manual time setting

• Daily alarm with snooze

• Indoor temperature (°C / °F selectable)

• E.L. Backlight

• mb/hPa or inHg selectable

• 12 to 24 hour weather forecast

• Daylight Saving Time (DST)

• Moon phase display

• Time zone display: Eastern, Central, Mountain

& Pacific

FUNCATION KEYS

SNOOZE/LIGHT bar:

TIME key:

ALM SET key:

UP key:

DOWN key:

°C/°F key :

mb/hPa or inHg key:

RESET key:

ALARM ON/OF switch:

PRODUCT DESCRIPTIONS

1.

LCD display

2.

UP key

3.

TIME key

4.

ALM SET key

5.

DOWN key

6.

°C/°F key

7.

mb/hPa or inHg key

8.

ALARM ON/OFF switch

9.

SNOOZE/ LIGHT bar

10. RESET key

11. Battery compartment

DISPLAY SYMBOLS

LCD display

1. Weather forecast & moon phase display

2. Clock display

3. Year/ month & date/alarm time display

4. Daylight savings time indicator

5. Signal strength indicator

6. Time zone map

7. Second /day of the week display

8. Atmosphere pressure display

9. Temperature display

NOTE:

Seconds and Day of the Week Display: Automatically

toggles every 30 seconds from Day to Seconds.

Toggles back to Seconds after 92 seconds.

INSTALLING OR REPLACING THE BATTERIES

• Begin by opening the battery compartment cover

at the back of the clock.

• Insert 2 AAA batteries (not included) into the battery

compartment and make sure the polarity is correct

by following the (+ or -) symbols engraved inside.

• Replace the battery whenever the display becomes

dim or difficult to read.

SELECT THE TIME ZONE ( WWVB VERSION ONLY)

Make sure the time zone is already set to appropriate

location. The default time zone is Pacific zone. If your

location is not of Pacific zone, please press the UP

key to set the desired Time zone.

RADIO CONTROLLED TIME FEATURE

After the first signal is received, the clock will

automatically seeks the atomic clock signal that is

transmitted by the National Institute of Standards and

Technology in Fort Collins, Colorado. Delete all other

words after “Colorado”.

SIGNAL STRENGTH INDICATOR FOR RADIO

CONTROLLED TIME SETTING

The signal indicator displays signal strength in 3 levels.

Wave segment flashing means time signals are being

received. The signal quality is indicated:

If the RC clock receives a successful signal, a

sync-time symbol will appear on the LCD.

Stop alarm sound and turn on

E.L. backlight. Pressing and

holding it for 8 seconds can

stop the current RC reception.

In normal time mode, press it

once to toggle between month

& date and year display. Keep

it pressed for 2 seconds to

enter time setting mode. In

setting mode, press it to step

the setting items.

In normal time mode, press it

to display Alarm time. In

Alarm time mode, keep it

pressed for 2 seconds to enter

alarm time setting mode. In

alarm time setting mode, press

it to step the setting items.

In setting mode, increase the

setting value. For WWVB

version, pressing UP key can

set the desired Time Zone.

In setting mode, decrease the

setting value. In normal time

mode, press it to toggle between

12 and 24hour format.

Toggle between °C and °F

format. Keep it pressed for 3

seconds to seek RC signal

instantly.

Toggle between mb/hPa and

inHg display.

In case of mal-function after

insert of battery, use a pin to

press the RESET key to

restart the clock.

In case of no display on LCD

while inserting batteries, use

a pin to press the RESET key

to activate the clock.

Switch alarm & snooze function

on or off.

10

11

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

8

9

7

ABOUT THE DAYLIGHT SAVINGS TIME (DST)

This clock has been pre-programmed to automatically

switch when daylight savings time is in effect. Your

clock will show “DST” on the display during this time.

NOTE:

With the pre-programmed DST feature, if you live in

an area where Daylight Savings Time is not observed,

the time display on your clock will read +/- one hour

during the DST time period.

SETTING THE TIME MANUALLY

To set the time, please follow these steps:

• In normal time mode, press the TIME key for 2

seconds until the HOUR digit flashes.

• Press UP or DOWN key to change the value of the

flashing digit.

• Press the TIME key again to step the setting items.

The setting sequence will be: Hour > Minute >

Second > Year > Month > Date > Day language.

• Press the UP or DOWN key to select the day

language:

GB=English FR=French DE=German ES=Spanish

IT=Italian

• Press TIME key to exit the setting mode.

NOTE:

In normal time mode, pressing the DOWN key will

toggle between the 12 and 24 hour formats.

SETTING THE ALARM

• In normal time mode, press ALM SET key to enter

alarm time mode.

• Press the ALM SET key for 2 seconds until the

alarm hour digit flashes.

• Press UP or DOWN key to increase or decrease the

value of flashing digit.

• Press ALM SET again to move through each setting.

The sequence will be: Hour > Minute.

NOTE:

12/24hour format of alarm time display are based on

the normal time format.

USING THE ALARM AND SNOOZE FUNCTION

• To activate the alarm, slide the [ALARM ON/OFF] to

the [ON] position, the bell indicator will appear on

the display.

• To deactivate alarm, slide the [ALARM ON/OFF]

button to the [OFF] position, the bell indicator will

disappear.

NOTE:

The snooze will be on automatically after activating

the alarm.

Normal Display

Hour Setting

Day Language Setting

Date Setting

Second Setting

Minute Setting

Month Setting

Year Setting

Alarm Mode

Alarm Hour Setting Alarm Minute Setting

Advertising