Part number identification electrical parameters, Switching output, Mounting plates – Omega Speaker Systems PSW32 User Manual

Page 4

Advertising
background image

PART NUMBER

PRESSURE RANGE

ELECTRICAL

PROOF/BURST

ANALOG OUTPUT

PSI

CONNECTION

PRESSURE – PSI

0-10 VOLT AND 4-20mA

PSW32B

0 – 580

(0 – 40)

DIN 43650

1450/2175 (100/150)

No

PSW32B-A

0 – 580

(0 – 40)

DIN 43651

1450/2175 (100/150)

Yes

PSW32C

0 – 1450 (0 – 100)

DIN 43650

2900/4350 (200/300)

No

PSW32C-A

0 – 1450 (0 – 100)

DIN 43651

2900/4350 (200/300)

Yes

PSW32D

0 – 2320 (0 – 160)

DIN 43650

4350/5800 (300/400)

No

PSW32D-A

0 – 2320 (0 – 160)

DIN 43651

4350/5800 (300/400)

Yes

Numbers in parentheses indicate measurement in bar.

Notes: Mounting plates included.

For hydraulic applications with pressure spikes or surges install a pressure snubber.
All pressure switches are shipped with mounting screws, o-ring and mating electrical connector.

DIN 43650 without analog output

DIN 43651 with analog output

1

+24V

3 U

out

I

max

= 1A

2

0V

4

4 – 20mA

5

0 – 10V

PE

U

I

U

I

Micro-

Controller

SP RP

p

=

E

2

PROM

(SP,RP)

Load

1

+24V

3 U

out

I

max

= 1A

2

0V

PE

I

Micro-

Controller

SP RP

p

=

E

2

PROM

(SP,RP)

Load

1.73 (44)

1.57 (40)

1.57 (40)

.47 (12)

.59 (15)

A

A

Ø.12 (3)

.94

(24)

1

/

4

– 18 NPT

.22 (5.5)

.22 (5.5)

View on 'A'

M5

.35 (9)

.45 (11.5)

.79 (20)

Mounting Plates

(Included)

1/4" NPT Pressure Port
304 Stainless Steel

All dimensions in inches (mm)

PART NUMBER IDENTIFICATION

ELECTRICAL PARAMETERS

Electrical connection

DIN 43650 Table A without analog output
DIN 43651 (7 pin), with analog output

Power supply (polarity safe)

18 to 32V DC

Permissible residual ripple

10% (within 18 to 32V)

Current consumption

<50 mA (plus load current)

SWITCHING OUTPUT

Switching mode

Open collector PNP switched to supply

(suited for inductive load)

Output voltage

Supply voltage minus 1.5V (approx)

Analog output

O to l0V and 4 to 20mA

Contact rating

Imax = 1A (short-circuit proof)

Switching time

< 5ms

Service life

100 million switching cycles

Switching logic

Signal “on” with rising pressure, if SP* > RP**
Signal “on” with falling pressure, if SP < RP

* SP = Switching point **RP = Reset point

E L E C T R O N I C P R E S S U R E S W I T C H F O R H Y D R A U L I C A P P L I C AT I O N S

Advertising