Omega Vehicle Security LV132 User Manual

Page 2

Advertising
background image

Sensor Pulled Through Interstitial

Sensor Pulled Through Interstitial

Sensor Pulled Through Interstitial

Sensor Pulled Through Interstitial

Sensor Pulled Through Interstitial

Space of Double-Wall Tank

Space of Double-Wall Tank

Space of Double-Wall Tank

Space of Double-Wall Tank

Space of Double-Wall Tank

Controller

LV132 Tip

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

SPECIFICATIONS

•••••

Input Voltage: 10-28 VDC

Current Consumption: Approximately 17mA
Output: TTL/CMOS Compatible
Output may sink 100mA up to 28 VDC

•••••

Not for use in freezing conditions (See Temperature Ranges)

•••••

Materials in contact with fluids are polysulfone, plastic, PVC,

stainless steel and polyolefin.

•••••

Repeatability: ±1mm

MAINTENANCE

MAINTENANCE

MAINTENANCE

MAINTENANCE

MAINTENANCE
Sensor may require a periodic cleaning of prism surface.

Chlorinated hydrocarbons must not be used for cleaning.

Chlorinated hydrocarbons must not be used for cleaning.

Chlorinated hydrocarbons must not be used for cleaning.

Chlorinated hydrocarbons must not be used for cleaning.

Chlorinated hydrocarbons must not be used for cleaning. A mild deter-

gent may be used to clean prism surface.

TEMPERATURE RANGES

TEMPERATURE RANGES

TEMPERATURE RANGES

TEMPERATURE RANGES

TEMPERATURE RANGES

PRESSURE RANGE

PRESSURE RANGE

PRESSURE RANGE

PRESSURE RANGE

PRESSURE RANGE

F

F

F

F

F

)))))

0°F to 176°F

0 to 50 PSI, Max.

Conductivity Sensors

1/4" NPT

Optional

LV132 Tip

E

lectro-Optic

Conductivity Sensor

Red: 10-28 VDC
Black: Ground
Green: Fuel/Oil
White: Conductive
Output

Label

(Electrical Rating)

1.10"

(27.94mm)

0.62"

(15.75mm)

3.22"

(81.79mm)

Cable (4) Conductor (PVC Jacket)

25 Ft to 25.5 ft Extended

(7.62 to 7.77m extended)

DIMENSIONS

DIMENSIONS

DIMENSIONS

DIMENSIONS

DIMENSIONS

C

C

C

C

C

)))))

-17.8°C to 80°C

P/N 156837

INSTALLATION - Sensor

INSTALLATION - Sensor

INSTALLATION - Sensor

INSTALLATION - Sensor

INSTALLATION - Sensor
When installed in accordance with this installation proce-
dure, the sensor is suitable for use in Class I, Division 1,
Groups C and D.

1. With protective shield attached, sensor can be pulled

through interstitial space of double-wall tank. Sensor can

also be placed loose in tank or reservoir.

2. Sensor may be installed in horizontal or vertical

positions, only.

3. Do not install sensor close to infrared sources.

4. Prism surface must be at least 2" from any reflective

surfaces.

5. Connect 10-28 VDC power to red lead; return to

( ) black lead.

Advertising