Operating instructions, Warning – Ozark Trail 842-A100-W User Manual

Page 6

Advertising
background image

5

DO NOT allow gasoline or other flammable vapors or liquids to come in contact with stove while

lighting or at any time during use of stove.

WARNING

Perimeter of base of stove

36"

36"

READ ALL SAFETY WARNINGS AND INSTRUCTIONS CAREFULLY.

OPERATING INSTRUCTIONS

Step 1

Make sure "Gas Leak Testing" from page 4 was completed
and the burner control knobs are in the "OFF" position and
stove is on a flat surface away from combustible material.

Step 2

Decide which burner to light first. Using a long match,
hold the flame beside burner. Turn the burner control knob
SLOWLY counter-clockwise until the burner lights.

WARNING: If the burner does not light within 5 seconds, turn

the burner control knobs "OFF" immediately. Wait
at least 5 minutes until gas fumes have dissipated
before attempting to light burner again.

Step 3

To light the second burner, reduce the flame on the first lit
burner and repeat Step 2 to the other burner.

WARNING: If second burner does not light within 5 seconds,

turn the burner control knobs "OFF" immediately.
Wait at least 5 minutes until gas fumes have
dissipated before attempting to light burner again.

Step 4

Adjust burner flame as necessary by using burner control
knob. Turn stove "OFF" using burner control knobs when
stove is not in use.

Step 5

Allow stove to cool completely, then follow instructions in
the "After-Use Safety" and "Proper Care & Maintenance"
sections of this manual.

OFF / Smaller Flame

ON / Larger Flame

Minimum clearance to

combustibles 36 inches from top

and side of stove burners

NOTE: Observe flame height and

color when lit. Flame
should have a blue center
and yellow tip.

Yellow

Blue

Burner

842-A100-W_CmpStove.qxd 5/5/03 09:43 AM Page 6

Advertising