2. Lift open the cassette compartment door.

3. Press the protection tab sensor, then press

RECORD

. The

tape head assembly moves out.

4. Use a cotton swab dipped in tape head cleaner or dena-

tured alcohol to clean the record/playback head, pinch
roller, tape guides, and capstans.

Cautions:

• Never touch the front surface of the record/playback head

with any metallic object.

• Do not use a tape demagnetizer on this product because

such demagnetizers can impair operation of the permanent
magnet erasing device.

Capstans

Tape Guides

Record/Playback Head

Pinch Roller

Protection
Tab Sensor

14-1121.fm Page 26 Thursday, July 1, 1999 2:42 PM