World-class resolution and precision.

Objective lens

Circular confocal
pinhole

LED light

CCD

Photomultiplier

Laser

World’s highest level of resolution

The optical system designed exclusively for use with 408-nm
laser light (violet opt system) prevents the occurrence of
aberrations associated with the use of a short-wavelength light
source, and brings the highest performance out of the 408-nm
light source. Such a high level of resolution has been made
possible by the confocal optical system having an optimized
circular pinhole and the high-
speed XY scanner with the
MEMS technology of Olympus.
With the world's highest-level
planar resolution, a line or space
of 0.12 µm can be resolved.
Additionally, the 0.01 µm height
resolution supports the user in
undertaking measurements of
microscopic surface profiles.

Basic concept of a light path in the violet opt system

Basic concept of the two-dimensional scanner

Multiple points
at peak
intensity

Intensity

Height

MEMS scanner

Incident light

Scan pattern

0.12 µm line and space 14,400x

Further advanced, the world’s highest level of
repeatability

Advanced optical techniques of Olympus accumulated over
years have made possible the planar measurement
repeatability of 3

σ

= 0.02 µm and the height measurement

repeatability of 3

σ

= 0.04 + 0.002L mm (L = measured length

in µm). A guide with high performance in terms of straightness
and a high-precision linear scale are used for Z-axis scanning.
These parts combined with the further advanced CFO search
function contribute to very high level of repeatability. The high
degree of reliability makes it possible for LEXT to meet the
highly demanding needs of diverse fields of research and
industry.

Measurements that can be trusted

Highly reliable data can be provided based on the strict
traceability system that is linked with the JCSS (Japan
Calibration Service System).

JCSS Japan Calibration Service System

Block Gauge

OLYMPUS

Stabilized He-Ne Laser

Calibration standard

Calibration block

LEXT (OLS3100)

Traceability chart

Japan (NMIJ/AIST)

CFO search function

The original I-Z curve is
drawn based on the upper,
high-luminance points, and
maximum luminance values
are calculated with high
accuracy by using an
advanced formula. The high
repeatability of LEXT is
made possible through the
height data being obtained
in this process.

Advertising