7.2. Scan Area and Resolution

The scan area is a circular area centered around the beam, which appears at various
resolutions.

Figure 3: Depth of field.

Resolution Symbology

PCS

Quiet Zone

Digits

Depth of Field (mm)

1.0 mm

CODE-39

0.9

25 mm

1

40 to 500

0.5 mm

CODE-39

0.9

18 mm

3

20 to 350

0.25 mm

CODE-39

0.9

10 mm

8

20 to 200

0.15 mm

CODE-39

0.9

7 mm

10

20 to 100

0.127 mm

CODE-39

0.9

5 mm

4

30 to 70

Conditions