I/O select (Sec. 3.3.7)

disable\

input Latch

Clock input

D/O latch CKT

RESET\ (Sec. 3.3.1)

Data

(Sec. 3.3.8)

D/I/O

disable

Buffer input

Clock input

D/I buffer CKT

Data

(Sec. 3.3.8)
























• When the RESET\ is in Low-state Æ all D/I/O operations are disabled
• When the RESET\ is in High-state Æ all D/I/O operation are enabled.
• If D/I/O is configured as D/I port Æ D/I= external input signal
• If D/I/O is configured as D/O port Æ D/I = read back of D/O
• If D/I/O is configured as D/I port Æ send to D/O will change the D/O latch

register only. The D/I & external input signals will not change.