STATUS INDICATORS

When the following indicators light up or blink on the operation panel or the following
alphanumeric codes appear in the display, solve the problem immediately referring
to both the table below and the relevant page.

Be sure to use only genuine OLIVETTI parts and supplies.

Indication

Cause and remedy

Page

Drum replacement
required indicator

Steadily
lit

Replacement of drum cartridge will be needed
soon. Prepare a new cartridge.

71

Blinking

Drum cartridge must be replaced. Replace it with
a new one.

59

TD cartridge
replacement
required indicator

Steadily
lit

Replacement of TD cartridge will be needed
soon. Prepare a new cartridge.

71

Blinking

TD cartridge must be replaced. Replace it with a
new one.

58

Misfeed indicator

Blinking

A misfeed has occurred. Remove the misfed
paper referring to the description of "MISFEED
REMOVAL".

64

SPF misfeed
indicator

Blinking

An original misfeed has occurred in the SPF.
Remove the misfed originals referring to the
description of "D: Misfeed in the SPF".

67

Power save indicator is
steadily lit.

The unit is in the preheat mode. Press any key to
cancel the preheat mode.

55

The unit is in the auto power shut-off mode.
Press the start (

) key to cancel the auto power

shut-off mode.

55

The paper tray indicator is
blinking.

The paper tray is not installed properly. Push the
tray into the unit securely.

"CH" is blinking in the
display.

The TD cartridge is not installed. Check if the
cartridge is installed.

58

"CH" is steadily lit in the
display.

Side cover is open. Close the side cover
securely by pressing the round projections near
the side cover open button.

"P" is blinking in the display.

The paper tray is empty, or single bypass has
been selected in the printer function.
Load paper.

15, 17

A misfeed has occurred in the paper tray or
single bypass. Remove the misfed paper.

64

A letter and a number appear
alternately.

The scan head locking switch is locked. Unlock
the scan head locking switch and turn the power
switch off/on.

9

A letter and a number appear
alternately.

The unit will not function. Turn the power switch
off and then switch it on, and if there is again an
error, remove the power cord from the outlet, and
contact your authorized service representative.