I. system start-up information, Caution, Warning – Oneida Air Systems 5 & 7.5 HP Direct Drive Cyclonic Dust Collectors User Manual

Page 3

Advertising
background image

2

I. System Start-Up Information

O.A.S. 2002

c

5 - 7.5 HP Direct Drive Owner’s Manual

1. Read the installation and maintenance instructions as well as the recommended
safety practices in this manual.

2. Install Ductwork completely:

A.) Seal ductwork with silicone sealant or duct tape.
B.) Have Dust Bin in place and sealed before running Dust Collector.

3. Wire Fan / Blower according to wire diagram on pg. 11 in this owner’s manual.

4. Have a licensed electrician check current draw on motor with all gates open. Current
draw should not exceed maximum motor amperage. (OAS is not responsible for
destroyed motors.)

Caution

The Direct Drive Fan / Blower makes the system top heavy!

Use extreme care when setting the unit up!

Warning

Check amperage draw during operation with all blast gates

open. Make certain amperage is not outside operating limit

indicated on motor plate!

Warning

If amperage is too high - shut down immediately!

(See troubleshooting section.)

Warning

Do not operate Fan / Blower unless Cyclone and Dust Bin

are in place. Motor will over heat!