Related auxiliary area words and bits function, Hint, Precaution – Omron SYSMAC CP CP1E-N@@D@-@ User Manual

Page 422: Sample program, 2 instructions

Advertising
background image

2 Instructions

2-386

CP1E CPU Unit Instructions Reference Manual(W483)

Related Auxiliary Area Words and Bits

Function

DATE(735) changes the internal clock
setting according to the clock data in
the four source words. The new inter-
nal clock setting is immediately
reflected in the Calendar/Clock Area
(A351 to A354).

Hint

The internal clock setting can also be changed from a Peripheral Device or the CLOCK WRITE FINS
command (0702).

Precaution

An error will not be generated even if the internal clock is set to a non-existent date (such as Novem-

ber 31).

In case this instruction is executed for E-type CPU Unit (CP1E-E

- ), the error flag will turn

ON and the instruction cannot be executed. For E-type CPU Unit, A351 to A354 is always 01-01-01
01:01:01 Sunday.

Sample program

When CIO 0.00 turns ON in the following example, the internal clock is set to 20:15:30 on Thursday,
October 9, 1998.

Name

Address

Operation

Clock data

A351 to A354

A351.00 to A351.07: Seconds (00 to 59) (BCD)

A351.08 to A351.15: Minutes (00 to 59) (BCD)

A352.00 to A352.07: Hours (00 to 23) (BCD)

A352.08 to A352.15: Day of the month (01 to 31) (BCD)

A353.00 to A353.07: Month (01 to 12) (BCD)

A353.08 to A353.15: Year (00 to 99) (BCD)

A354.00 to A354.07: Day of the week (00 to 06) (BCD)

00: Sunday, 01: Monday, 02: Tuesday, 03: Wednesday, 04: Thursday,

05: Friday, 06: Saturday

S1

S+1

S+2

S+3

Internal clock

New setting

00

Minutes

Day

Year

Day of week

Seconds

Hour

Month

CPU Unit

DATE

D100

0.00

S

S:D100

15

30

15

7

8

D101

09

20

15

7

8

D102

98

10

15

7

8

D103

00

04

15

7

8

0

0

0

0

Second

Hour

Minute

Day of
the month

Year

Month

Always
set to
00.

Day of the week