Omega Speaker Systems HH802W User Manual

Hh802w, Introduction, Safety information

Advertising
background image

HH802W

OMEGAnet

®

®

On-Line Service

omega.com

Internet e-mail

[email protected]

Servicing North America:

U.S.A:

One Omega Drive, Box 4047
Stamford, CT 06907-0047

ISO 9001

Tel: (203) 359-1660

FAX: (203) 359-7700

Certified

e-mail: [email protected]

Canada:

976 Bergar
Laval (Quebec) H7L 5A1, Canada
Tel: (514) 856-6928

FAX: (514) 856-6886

e-mail: [email protected]

For immediate technical or application assistance:

U.S.A

Sales Service: 1-800-826-6342/1-800-TC-OMEGA

®

and

Customer Service: 1-800-622-2378/1-800-622-BEST

®

Canada:

Mexico:

En Espan ol: (001) 203-359-7803
e-mail: [email protected]
FAX: (001) 203-359-7807 [email protected]

Servicing Europe:

Benelux:

Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: +31 (0)20 3472121

FAX: +31 (0)20 6434643

Toll Free in Benelux: 0800 0993344
e-mail: [email protected]

Czech

Frystatska 184, 733 01 Karviná, Czech Republic

Republic:

Tel: +420 (0)59 6311899

FAX: +420 (0)59 6311114

Toll Free: 0800-1-66342

e-mail: [email protected]

France:

11, rue Jacques Cartier, 78280 Guyancourt, France
Tel: +33 (0)1 61 37 2900

FAX: +33 (0)1 30 57 5427

Toll Free in France: 0800 466 342
e-mail: [email protected]

Germany/

Daimlerstrasse 26, D-75392 Deckenpfronn, Germany

Austria:

Tel: + 49 (0)7056 9398-0

FAX: +49 (0)7056 9398-29

Toll Free in Germany: 0800 639 7678
e-mail: [email protected]

United

One Omega Drive, River Bend Technology Centre

Kingdom:

Northbank, Irlam, Manchester

ISO 9002

M44 5BD United Kingdom

Certified

Tel: +44 (0)161 777 6611

FAX: +44 (0)161 777 6622

Toll Free in United Kingdom: 0800-488-488
e-mail: [email protected]

It is the policy of OMEGA Engineering, Inc. to comply with all
worldwide safety and EMC/EMI regulations that apply. OMEGA
is constantly pursuing certification of its products to the
European New Approach Directives. OMEGA will add the CE
mark to every appropriate device upon certification.
The information contained in this document is believed to be
correct, but OMEGA accepts no liability for any errors it
contains, and reserves the right to alter specifications without
notice.

These products are not designed for use in, and

should not be used for, human applications.

INTRODUCTION

This instrument is a 5 digit, compact-sized portable

digital thermometer designed to use external K-type and J
type thermocouples as temperature sensor. Temperature
indication follows Reference Temperature/Voltage Ta-
bles (N.I.S.T. Monograph 175 Revised to ITS-90) for K-
type and J-type thermocouples. Two K-type thermocou-
ple are supplied with the thermometer.

SAFETY INFORMATION

It is recommended that you read the safety and opera-

tion instructions before using the thermometer.

WARNING

To avoid electrical shock, do not use this instrument

when working voltages at the measurement surface

over 24V AC or DC.

WARNING

To avoid damage or burns, do not make temperature

measurement in microwave ovens.

CAUTION

Repeated sharp flexing can break the thermocouple

leads. To prolong lead life, avoid sharp bends in the

leads, especially near the connector.

FEDERAL COMMUNICATIONS

COMMISSION

This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two condi-
tions:(1) this device may not cause harmful interfer-
ence, and (2) this device must accept any interference
received, including interference that may cause unde-
sired operation.

NOTE

This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection. This equipment gener-
ates, uses and can radiated radio frequency energy and,
if not installed and used in accordance with the in-
structions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation If
this equipment does cause harmful interference to ra-
dio or television reception, which can be determined
by turning the equipment off and on, the user is en-
couraged to try to correct the interference by one or
more of the following measures:

- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and

receiver.

- Connect the equipment into an outlet on a circuit dif-

ferent from that to which the receiver is connected.

- Consult the dealer or an experienced radio/TV tech-

nician for help.

Shielded interface cables must be used in order to
comply with emission limits.

Changes or modifications not expressly approved by

the party responsible for compliance could void
user‘s authority to operate the equipment.

WIRELESS NOTE

Wireless receiver must keep a distance at least 40cm

from the meter and meter to meter must keep a dis

tance at least 30cm.

SPECIFICATIONS

ELECTRICAL

Measurement Range:
J-TYPE -200°C to 1050°C, (-328°F to 1922°F)
K-TYPE -200°C to 1370°C, (-328°F to 2498°F)
Resolution: 0.1°C or 0.2°F
Accuracy: Accuracy is specified for operating tempera-
tures over the range of 18°C to 28°C (64°F to 82°F),
year, not including thermocouple error.
±(0.05% rdg + 0.3°C) -50°C to 1370°C
±(0.05% rdg + 0.7°C) -50°C to -200°C
±(0.05% rdg + 0.6°F) -58°F to 2498°F
±(0.05% rdg + 1.4°F) -58°F to -328°F
Temperature Coefficient:
0.1 times the applicable accuracy specification per
from 0°C to 18°C and 28°C to 50°C (32°F to 64°F
82°F to122°F).
Input Protection:
24V dc or 24V ac rms maximum input voltage on
combination of input pins.
Maximum Differential Common Mode Voltage
(Maximum Voltage between T1 and T2 during meas-
urement):
1volt.
Reading Rate: 1 time per second.

Wireless Features:

Frequency range: 904~927.83MHz
Low current consumption les than 5 to 20mA
Viewable distance 25M.

ENVIRONMENTAL

Ambient Operating Ranges:
0°C to 50°C (32°F to 122°F) <80% R.H.
Storage Temperature:
-20°C to 60°C (-4°F to 140°F) <70% R.H.

GENERAL

Display: 5 digit liquid crystal display (LCD).
Overload: “----.-” or “OL” is display.
Battery: 1.5V x 4 PCS (SIZE AAA) UM-4 R03.
Battery Life: 190 hours typical with carbon zinc battery.
Auto power off: 30 minutes, press power key to resume
operation.
Dimensions: 160mm(H) x 83mm(W) x 38mm(D).
Weight: Approx. 265g including batteries.
Supplied Thermocouples (2 per input):
1 meter (40”) type K insulated beaded wire thermoco
ple. Maximum insulation temperature is 482°C (900°F).
Thermocouple accuracy is ±1.1°C or 0.4% of reading
(whichever is greater) from 0°C to 1250°C.

M4550/0807

Shop online at: omega.com e-mail: [email protected]

For latest product manuals: omegamanual.info

INSTRUCTION

SHEET

MADE IN TAIWAN

Advertising