1. RS232 (Optical Interfaced) Port

2. Sockets of thermocouples T1

3. Sockets of thermocouples T2

OPERA

TING INSTRUCTIONS

Operational Mode

There are three operation modes–Normal, Shift, and

Setup Mode.

Normal Mode:

This is the default mode; the operating functions for the

normal mode are printed on the top of each button in white.

Shift Mode:

The operating functions for the shift mode are printed in

yellow on the buttons. While in the normal mode, push

the SHIFT

button to switch to shift mode. At the lower

-

righthand corner of the display panel, the word “Shift” is

displayed to indicate shift mode. T

o

switch back to normal

mode, press the SHIFT

button.

Setup Mode:

The operating functions for the setup mode are printed

in between two bracket signs “[ ]“ on each button. Press

the SET[ ] button in normal mode to switch to setup mode,

the indicator “SET” is shown on the left side of the display

panel. T

o

switch back to normal mode, press the SET[ ]

button.

Normal Mode:

The following functions can only be used in the normal

mode.

(1)

I

Power

Button

The“

I

” button turns the thermometer on or of

f. When

entering data set mode, the power of

f function is disabled.

(2) “Limits” Button (only main display)

The limits function will alert the user when a measure-

ment exceeds a specified limit. T

o

set the limit values, refer

to limits function in the setup mode.

Press the [Limits] button to activate the limits function; the

word “LIMIT” should be displayed on the LCD.

When the value of the main display exceeds the Hi limit, the

word “Hi” will be displayed and the thermometer will beep

in an interval frequency

. If the value of the main display is

lower then the Lo limit, the word “Lo” will be displayed

and the thermometer will beep in a continuous frequency

.

In Limits function, on K or J T

ype, and with the scale of

temperature at °F

, the reading counts should be times 10.

(ex: 2100°F means 21000 counts)

T

o

exit the Limits function, press the [Limits] button.

(3) “

button

The backlight function is represented by this button “

Pressing the button will turn the backlight on or of

f in the

”.

LCD.

(4) “SA

V

E/READ” button

The Read Data function works in conjunction with the

Save function in the Shift mode, it is used for reading saved

data. The Save function can be activated in Shift mode.

Press the SA

VE/READ button to activate the Read Data

function; the word “READ” should be displayed on the

LCD. T

o

navigate around the Saved Data table, press the

overlay “SECOND” button until the “#” sign is displayed on

the second display panel. The location of the read pointer

within the Saved Data table will be displayed. The arrow

buttons on the overlay are used for scrolling through the saved

data. Pressing the smaller arrow “

” or “

” retrieves the

next saved data. Pressing the lar

ger arrow “

” or “

will retrieve the next ten saved data. Pressing the overlay

“ESC” button deactivates the read data function.

(5) “LOG/READ” button

The Log/Read function works in conjunction with the log

function, it is used for reading the log data. The log function

can be activated in the shift mode. Press the LOG/READ

button to activate the read log function; the word “READ”

should be displayed on the LCD. Press the overlay SEC-

OND button to rotate through following display menus:

T1, T2, GRP

, and #.

T1 and T2: Displays the T1 or T2 saved value.

GRP: Displays the current group number

.

#: Displays the current location of the read pointer within

a selected group. The arrow buttons on the overlay are used

for scrolling through the data and groups. Press the smaller

arrows “

”or “

” to retrieve the next log data or

group. Press the lar

ger arrows “

” or “

” to retrieve

the next ten log data or groups. T

o

navigate around the log

data and groups, press the overlay SECOND button till

GRP

appears in the second display panel, and then select

the group using the arrows, then press the SECOND button

again till the “#” sign is displayed. The location of the read

pointer in the selected group will be displayed, and then use

the arrows to scroll through the data. Pressing the overlay

“ESC” button deactivates the read data function.

(7) HOLD mode (only main display)

When HOLD mode is selected, the thermometer holds

the present readings and stops all further measurements. T

o

activate the data hold mode, press the HOLD button, and

“HOLD” is displayed on the LCD. Pressing the HOLD

button again cancels the function, and the instrument will

automatically resume measurements.

(8) MIN/MAX with time r

ecord mode (only main

display)

The MIN/MAX function records the highest and lowest

value recorded, and it calculates the average reading, and

recorded. Press the MIN/MAX button again to rotate

the dif

ferences of MAX to MIN. Press MIN/MAX button

to enter the MIN/MAX recording mode. The beeper emits

a tone when a new minimum or maximum measurement is

through the current readings:

MAX: The highest measurement recorded.

MIN: The lowest measurement recorded.

MAX-MIN: The dif

ference of the highest and the lowest

measurement.

A

VG: The average values of the measurements. This mode

works in conjunction with the hold function, pressing the

HOLD button will stop the recording and measurements

(Previously recorded readings are not erased). Press HOLD

button again to resume recording and measurements. T

o

prevent accidental loss of MIN, MAX and A

V

G data, the

MIN/MAX function can only be cancelled by pressing and

holding down the MIN MAX key for more than 2 seconds.

The Automatic Power Of

f function, and the power

, C/F

,

REL, SET

, Hi/Lo Limits, TYPE, T1/T2 buttons are also

disabled.

(10) “T1/T2” button (MAIN display)

The input selection button [T1/T2] selects the input

for the main display panel, T1 thermocouple or T2

thermocouple. Press the T1/T2 button to switch between

the two inputs. When meter is turned on, it is set to the

display that was last in use.

(1

1) “T1/T2” button (SECOND

display)

The input selection button [T1/T2] selects the input for

the second display panel, T1 thermocouple or T2 thermo-

couple. Press the T1/T2 button to switch between the two

inputs. When meter is turned on, it is set to the display that

was last in use.

(12) “T1-T2/TIME” button (THIRD display)

The input selection button [T1/T2] selects the system

time and date, or the dif

ferential between the two thermo-

couples (T1-T2) for the third display panel. Press the T1/

T2 button to switch the display options. When meter is

turned on, it is set to the display that was last in use.

SHIFT

MODE

The following functions can only be used in the shift mode.

(2) “C/F” button

Press the C/F button to select the temperature scale,

readings can be displayed in Celsius (C) or Fahrenheit

(F). When the thermometer is turned on, it is set to the

temperature scale that was last in use.

(4) “SA

V

E” button

The save function stores the T1, T2 data in nonvolatile

memory

. Press the SA

VE button to save the current data.

The word SA

VE is displayed to indicate the data are saved.

The build in memory can store up to 128 data. The data can

be read using the read function in the normal mode.

(5) “LOG” button

The data log function continuously records the data

according to a specified time interval. The time interval can

be set using the interval time setup function [INVT] in the

setup mode. Press the LOG button to activate the log

function; the indicator “LOG” and “MEM” will be dis-

played on the LCD. There are 16 groups that are used for

storing the log data, and each group uses 64 data slots. If

the current log session exceeds 64 data, the log function

will automatically use the next group to store the following

data. A

maximum of 1024 data can be saved in one log

session. Press the LOG button again to exit the data log

function.

(6) “CLR ?” button

The CLR function clears all the saved and logged data in

memory

. When the CLR button is pressed, indicator

“MEM” is displayed and the “CLR” word on upper

-right

of LCD will blink. Pressing “ENTER” button printed on

the overlay in white word to clear all saved and logged data

or “ESC” button to exit this function.

(7) “REL” button (only main display)

The relative value function can be used for comparing the

saved reference value with other measurements. Press the

“REL” button to store the current measurement as the

reference value, and the “REL” should be displayed on the

right part of the LCD. The next measurement will display

the relative value compared to the reference value.

Press “REL” button again to clear the reference value and

deactivate the relative value measurement function.

(8) “[APO]” button

Press the [APO] button to trigger “Auto power of

f“

function on or of

f. In this function, the indicator “APO” is

shown at the upper lefthand panel of the LCD. When APO

(Auto power of

f) is enabled, it will automatically turn the

thermometer of

f if the key switch is inactivated according to

to the set time (the default time for APO is 5 minutes).

Press the Power button to resume operation.