Specifications, Jratings – Omron G3M User Manual

Page 2

Advertising
background image

2

Solid State Relay

G3M

Ordering Information (continued)

Isolation

Input terminal

pitch

Zero cross

function

Indicator

Rated output load

(Applicable output load)

Rated input voltage

Model

Phototriac

5.08 mm

Yes

No

2 A at 100 to 240 VAC

(2 A t 75 t 264 VAC)

5 VDC

G3M-202P-US-4

(2 A at 75 to 264 VAC)

12 VDC
24 VDC

3 A at 100 to 240 VAC

(3 A t 75 t 264 VAC)

5 VDC

G3M-203P-4

(3 A at 75 to 264 VAC)

12 VDC
24 VDC

5 A at 100 to 240 VAC

(5 A at 75 to 264 VAC)

5 VDC

G3M-205P-4

(5 A at 75 to 264 VAC)

12 VDC
24 VDC

No

2 A at 100 to 120 VAC

(3 A t 75 t 132 VAC)

5 VDC

G3M-102PL-US-4

(3 A at 75 to 132 VAC)

12 VDC
24 VDC

2 A at 100 to 240 VAC

(2 A t 75 t 264 VAC)

5 VDC

G3M-202PL-US-4

(2 A at 75 to 264 VAC)

12 VDC
24 VDC

3 A at 100 to 240 VAC

(3 A t 75 t 264 VAC)

5 VDC

G3M-203PL-4

(3 A at 75 to 264 VAC)

12 VDC
24 VDC

5 A at 100 to 240 VAC

(5 A t 75 t 264 VAC)

5 VDC

G3M-205PL-4

(5 A at 75 to 264 VAC)

12 VDC
24 VDC

Note: 1. TÜV marking is available with “-UTU” in place of “-US” on the part number.

2. VDE versions available. Contact your local OMRON representative.

Specifications

J

RATINGS

Input

Rated voltage

Operating voltage

Impedance

Voltage levels

Must operate voltage

Must release voltage

5 VDC

4 to 6 VDC

300 Ω ±20%

4 VDC max.

1 VDC min.

12 VDC

9.6 to 14.4 VDC

800 Ω ±20%

9.6 VDC max.

24 VDC

19.2 to 28.8 VDC

1.6 kΩ ±20%

19.2 VDC max.

Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions.

Output

Model

Rated voltage

Applicable load

Load voltage

Load current

Inrush current

G3M-102PL-US (-4)

100 to 120 VAC

75 to 132 VAC

0.1 to 2 A

30 A (60 Hz, 1 cycle)

G3M-202P(L)-US (-4)

100 to 240 VAC

75 to 264 VAC

G3M-203P(L) (-4)

0.1 to 3 A

45 A (60 Hz, 1 cycle)

G3M-205P(L) (-4)

0.1 to 5 A

Advertising