2.2 Run InstaCal

TM

To run InstaCal

TM

in the various forms of Windows, find the file named InstaCal.exe

using your file management system and double click your mouse on it. In DOS simply
type instacal and press the Enter key.

Once running, InstaCal

TM

provides four sub-menus (plus exit).

1. Select Install (either highlight it and hit enter of double click your
mouse on it).

2. Select Board #0 (select another number if Board #0 is already installed)

3. Select Board Type

4. Move through the selections and highlight the particular board you
are installing (e.g. CIO-RELAY08 or CIO-RELAY16/M).
Either double click on the board or hit enter.

5. The board’s default settings are then displayed. The board’s defaults are:

BASE ADDRESS:

300H (768 Decimal)

WAIT STATE

OFF

6. You are now ready to install the board in your computer. Open your PC (after
turning off the power) and install the board. After the board is installed and the
computer is closed up, turn the power back on.

7. Run InstaCal

TM

again, and at the main menu select Test.

a. Select the board you just installed
b. Select Internal Test
c. The internal control registers of the board will then be tested. If this test
is successful, your board is installed correctly. If not, you likely have
a base address conflict, or have the base address switch set incorrectly.
Please refer to the next chapter for more information regarding selecting
and setting the base address.

d. If the Internal Test is completed successfully, you may want to check
that the I/O pins are working correctly. To check this select
External Test and follow the instruction provided. This will
require the use of an ohmmeter.

3

6 SPECIFICATIONS

6.1 CIO-RELAY08, 16, 24 and 32 (standard versions)

POWER CONSUMPTION
+5V supply

510 mA typical plus 22 mA per active (on)
relay

GENERAL SPECIFICATIONS
Number

8, 16, 24, or 32

Contact arrangement

Form C (SPDT)

Contact rating

3A @ 120V A.C or 28V D.C. resistive

Contact type

Gold overlay silver

Contact resistance

100 milliohms max.

Operate time

20 milliseconds

Release time

10 milliseconds max.

Life expectancy

10 million mechanical operations min.

ENVIRONMENTAL
Vibration

10 to 55 Hz (Dual amplitude 1.5mm)

Shock

10G (11 milliseconds)

Dielectric isolation

500V (1 minute)

Life Expectancy

1 Million Operations Electrical
100,000 Operations @ Full Load