Iris i/o connector, External 12v battery (optional) – Optiquest iRIS 320 User Manual

Page 60

Advertising
background image

iRIS 220 / iRIS 320, V1.19 User Guide - 58

58

iQuest (NZ) Ltd - PO Box 15169, Hamilton, New Zealand Tel: +64 7 857-0810 Fax: +64 7 857-0811 Email: [email protected]

6.6 Connecting SDI-12 Instruments. (iRIS 320 / iRIS 320V only)


SDI-12 instruments should be connected as shown in the diagram below.

See Section 4.3.3 for information on using the SDI-12 terminal mode to access SDI-12 instruments directly.

Also, refer to Appendix C – SDI-12 (iRIS 320 / 320V only) for detail on the SDI-12 specification.

NOTE: The original (PCB revision 1.1) iRIS 320 / iRIS 320V models supported the connection of SDI-12
instruments via a psuedo SDI-12 interface. See Section 13.3 in Appendix E.



TOP














BOTTOM


IRIS I/O Connector



AI4
AI3
AI2
AI1
AGND
5VOP
DI2
DI1
DO2
DO1
SDI-12
DGND
12V+
GND (-)
VIN+
GND (-)

- +

External

12V Battery

(Optional)

DATA

SDI-12

+12V

Instrument(s)

0V

Charging source
e.g solar panel

Advertising