OS35

Infrared Temperature Sensor
Installation Instructions

1. Install OS35 as close as practical to view target material to be measured
2. Wire OS35 with Red to Positive Power, Black to Ground, White to Positive

Output Signal, and Green to Reference Output Signal

3. Measure actual temperature of target material with OS950 Thermometer or

any reliable reference

4. Adjust “offset”, “zero”, or “low cal” on input device to match reading to ac-

tual thermometer reading

5. Installation calibration complete

*Six counts off one count on
**Six counts on one count off

ERROR MESSAGES

Condition

Priority

LED Display

0-5V

0-10V

4-20mA

RS-232

Low Power

1

OFF

Under 0.1V

Under 0.1V

Under 4mA

Not Implemented

Hardware Internal

Errors

2, 13

Uniform Flash

Over 4.9V

Over 9.8V

Over 19.7mA

Not Implemented

Vsig-Offset High

3

Uniform Flash

Over 4.9V

Over 9.8V

Over 19.7mA

Not Implemented

Vsig-Offset Low

4

Uniform Flash

Over 4.9V

Over 9.8V

Over 19.7mA

Not Implemented

EMI

5

Uniform Flash

Over 4.9V

Over 9.8V

Over 19.7mA

Not Implemented

Range Error

6

Uniform Flash

Over 4.9V

Over 9.8V

Over 19.7mA

Not Implemented

High Ambient

7

Long Flash**

Over 4.9V

Over 9.8V

Over 19.7mA

Not Implemented

Low Ambient

8

Short Flash*

Over 4.9V

Over 9.8V

Over 19.7mA

Not Implemented

Too Much Heat

Flow

9

Long Flash**

Over 4.9V

Over 9.8V

Over 19.7mA

Not Implemented

Too Little Heat

Flow

10

Short Flash*

Over 4.9V

Over 9.8V

Over 19.7mA

Not Implemented

High Target

11

Long Flash**

Over 4.9V

Over 9.8V

Over 19.7mA

Not Implemented

Low Target

12

Short Flash*

Over 4.9V

Over 9.8V

Over 19.7mA

Not Implemented