Oregon Scientific Radio Controlled Wireless Weather Station C8266B User Manual

Down up c / f sync o o

Advertising
background image

C8266B-PD09535M (DCF) -EN Size: A4

EN

RADIO CONTROLLED

WIRELESS WEATHER STATION

MODEL:JW102

USER MANUAL

BRIEF INTRODUCTION

Thank you for your purchase of this delicate Wireless

Weather Station. The utmost care has gone into the

design and manufacture of your clock. Please read

these instructions carefully and keep the manual well

for future reference.
The multifunctional weather station is equipped with

many functions providing thorough weather information

to you. The receiver unit has a clear, easy-to-read

display that shows the indoor temperature, moon phase,

time, month, date as well as the temperature measured

and transmitted from the remote sensors. It is able to

receive and display readings from up to 3 remote

sensors.
The 433 MHz technology means no wire installation is

required and you can place the sensors anywhere you

like.
With radio controlled function, the current time and

date are automatically synchronized with the time signal

transmitted from Germany(DCF).

MAIN FEATURES:

WEATHER STATION

1. CLOCK WINDOW:

Displays time, year, signal strength indicator,

daylight savings time (DST), alarm icons.

2. CALENDAR AND MOON PHASE WINDOW:

Displays the month, date, day of the week, alarm

time as well as the moon phase.

3. WEATHER FORECAST AND TEMPERATURE

WINDOW:

Shows the current indoor & outdoor temperature,

the maximum/minimum temperature as well as

the current channel.

4. TIME key:

In normal time mode, press it to enter alarm1

and alarm2 time mode.

Press and hold it for 2 seconds to enter the

normal time setting mode.

In normal time setting mode, press it to step the

setting items.

5. CHANNEL key:

Press it to switch among channel 1, 2 and 3.

Press and hold it for 2 seconds to show the

channels automatically, and press it once again

to exit the automatic display mode.

6. MAX/MIN key:

Press it to show the maximum and minimum

temperature records.

Press and hold it for 3 seconds to delete the

max. and min. records.

7. SNOOZE key:

Press it to stop the current alarm when it is

sounding.

8. ALARM ON/OFF key:

In normal time mode, press it to turn on/off alarm1

& alarm2.

In alarm time mode, press it to turn on/off alarm

and temperature pre-alarm.

In alarm time mode, press and hold it for 2

seconds to enter the alarm time setting mode.

In alarm time setting mode, press it to step the

setting items.

Press it once to stop the current alarm when it is

sounding.

9. RESET key:

Press it to reset all values to default values.

In case of malfunction, the unit may be required

to reset.

10. UP key:

In normal time mode, press it to switch between

M-D (Month-Date) and D-M (Date-Month)

formats.

In time setting mode, press it to increase the

setting values.

Press and hold it for 3 seconds to receive the

RC signal for reception testing.

11. DOWN key:

Press it to switch 12/24-hour format.

In time setting mode, press it to decrease the

setting values.

12. SYNC key:

Press and hold it for 3 seconds to turn on/off the

signal reception of transmitter (433 MHz)

manually.

13. °C/°F key:

Press it to switch between Celsius and Fahrenheit.

14. WALL-MOUNTING HOLDER:

Use it to support the main unit in the wall

mounting.

15. BATTERY COMPARTMENT:

Accommodates 4 AA size batteries.

16. TABLE STAND:

Use it to stand the clock on the desktop.

TRANSMITTER

1. LCD indicator:

Displays the current temperature monitored by

the remote unit.

2. CHANNEL slide switch:

Assign the transmitter to Channel 1, 2 or 3.

3. RESET key:

Press it to restart the transmitter and return all

values to default values.

4. °C/°F key:

Switches between Celsius and Fahrenheit.

5. BATTERY COMPARTMENT:

Accommodates 2 AA size batteries.

6. BATTERY DOOR
7. WALL-MOUNTING HOLDER:

Use it to support the transmitter on the wall.

8. TABLE STAND:

Use it to stand the transmitter on the desktop.

RECEPTION OF TRANSMITTER SIGNAL

OPERATING THE WEATHER STATION

1.

Remove the battery door and insert 4 AA size

batteries into the battery compartment as per

the polarity information marked on the battery

compartment.

2.

Replace the battery door.

3.

Press “RESET” key to restart the clock.

4.

Press “CHANNEL” key to set the desired

channel.

Note:
1.

When the transmitter signal is received, the

icon “

” will be shown and flash for 3 times.

2.

The building material and position of receiver

and transmitter affect the effective range. So

try various locations to obtain the best result.

3.

Place the units away from metal objects and

electrical appliances to minimize the interference.

Position the receiver within the effective

transmission range: 30 meters in usual

circumstances.

OPERATING THE TRANSMITTER

1.

Remove the transmitter from the stand and

open the battery door.

2.

Insert 2 AA size batteries into the battery

compartment as per the polarity information

marked on the battery compartment.

3.

Slide “CHANNEL” switch to synchronize the

channel with receiver.

4.

Press “RESET” key individually by a pin to

confirm the channel setting.

5.

Press “°C/°F” key to select the temperature

unit.

6.

Replace the battery door.

Note:
1.

To receive the transmitter signal, the channels

of receiver and transmitter must be

synchronized.

2.

The icon “

” will flash for 3 times when the

signal is being transmitted.

3.

Once the channel is assigned to a transmitter,

you can only change it by removing the batteries

or resetting the unit.

RECEPTION OF RADIO CONTROLLED

TIME SIGNAL

The time and date are radio-controlled. The current

time and date are automatically synchronized with the

signal transmitted from Germany (DCF).
When used for the first time (after inserting the

batteries or pressing “RESET” key), the clock will start

to receive the signals and the reception display will

flash in 8 seconds.

DAYLIGHT SAVINGS TIME (DST)

The clock has been programmed to automatically

switch when the daylight savings time is in effect.Your

clock will show “DST” during the summe.

SIGNAL STRENGTH INDICATOR

The signal indicator displays signal strength in 4 levels.

Wave segment flashing means time signals are being

received. The signal quality could be classified into 4

types:

Note:
1.

The unit will automatically search for the time

signal at 2:00 (3:00 or 4:00 is also available if

the signal was not received at 2:00), 8:00, 14:00

and 20:00 each day.

2.

Always place the unit away from interfering

sources such as TV set, computer etc.

3.

Avoid placing the unit on or next to metal plates.

4.

Closed area such as airport, basement, tower

block or factory is not recommended.

5.

Do not start reception in moving articles such

as vehicles or trains.

TIME AND CALENDAR MANUAL SETTING

If you are out of reach of the Radio Controlled

transmitter or if the reception is not reachable, the

time and calendar can be set manually. As soon as the

signal of transmitter is received again, the clock will

automatically synchronize with the exact time and

calendar.

1.

Press and hold “TIME” key for 2 seconds until

the Year digit flashes.

2.

Press “UP” or “DOWN” key to change its value.

3.

Press “TIME” key once until the Month digit

flashes.

4.

Press “UP” or “DOWN” key to change its value.

5.

Repeat the above operations (

point 3, 4) to set

the below items in this order: Date > Hour >

Minute > Second > Day language > +/-23 hours

time difference.

6.

Press “TIME” key to save and exit the setting

mode, or let it exit automatically 30 seconds

later without pressing any key.

Note:
1.

Through

“+/-23 hours time difference” setting,

the precise time of another area will be shown.

2.

The 5 languages weekday settings are

represented by the below abbreviations:

GB=English FR=French DE=German

ES=Spanish IT=Italian.

ALARM TIME SETTING

1.

In normal time mode, press “TIME” key to enter

the alarm1 (alarm2) time mode.

2.

Press and hold “ALARM ON/OFF” key for 2

seconds until the alarm Hour digit flashes.

3.

Press “UP” or “DOWN” key to change its value.

4.

Press “ALARM ON/OFF” key once until the alarm

Minute digit flashes.

5.

Press “UP” or “DOWN” key to change its value.

6.

Press “ALARM ON/OFF” key to save and exit

the setting mode, or let it exit automatically 30

seconds later without pressing any key.

Note:
1.

The alarm will be automatically turned on when

you set the alarm time.

2.

The dual-alarm (alarm1 & alarm2) design of this

unit provides you with more convenience, and

you can set two-alarm time if needed.

USING ALARM & TEMPERATURE

PRE-ALARM FUNCTIONS

1.

Set the alarm time as the above section with

alarm1 (alarm2) turned on when you set the alarm

time.

2.

In alarm1 (alarm2) time mode, press “ALARM

ON/OFF” key once to turn on the temperature

pre-alarm with the icon “

” displayed.

4
5
6
7

8

1

2

3

DOWN

UP

C / F

SYNC

O

O

14

15

16

DOWN

UP

C / F

SYNC

O

O

9 10

11 12 13

3

2

5

7

1

4

7

6

8

433 MHz

THERMO SENSOR

433 MHz

THERMO SENSOR

No signal quality

Acceptable signal quality

Excellent signal quality

Weak signal quality

DOM

LUN

MAR

MIE
JUE

VIE

SAB

DOM

LUN

MAR
MER

GIO

VEN
SAB

English

SON
MON

DIE
MIT

DON

FRE

SAM

German

DIM

LUN

MAR
MER

JEU

VEN
SAM

French

Spanish

Italian

SUN

MON

TUE

WED

THU

FRI

SAT

Advertising
This manual is related to the following products: