LightJet 430 User Guide

×

see copyright, disclosure, use and duplication information on pg ii

45574-F

2-4

5. If the filter is damaged, replace it. Contact Océ (see “Product Support, Documentation and

Service” on page ii) for a replacement filter (part #39958).

6. Re-install the filter and grill.

NOTE

If anything other than clean dry air is sent to the air bearings in the
micropositioner, the air ports within the micropositioner can become clogged.
There is no way to repair this in the field and the entire LightJet must be
returned to the factory for repair.

Coalescing Filter

The coalescing filter is located just inside the right side door. Examine the filter monthly,
checking for the following:

§ Dirt

§ Liquid or oil in the bowl - should not be above the lower baffle holding the filter

element.

§ Differential pressure indicator - should not extend more than half way into the clear

dome located above the retaining ring on top of the filter body.

If one or more of the above conditions exists, replace the coalescing filter. Otherwise, replace once
per year. To examine or replace the coalescing filter:

CAUTION

CAUTION: THE FILTER CONTAINER IS UNDER PRESSURE (60 PSI). TURN
OFF THE HOUSE AIR SUPPLY AND DEPRESSURIZE ALL AIR LINES
CONNECTED TO THE FILTER ASSEMBLY. THERE IS A RISK OF PERSONAL
INJURY IF RELEASED UNDER PRESSURE.

ATTENTION: LA CARTOUCHE DU FILTRE EST SOUS PRESSION (4.1 BAR).
DÉCONNECTEZ LA SOURCE D'ALIMENTATION D'AIR COMRIMÉ ET
DÉPRESSURISEZ TOUTES LES LIGNES À AIR CONNECTÉES AU PORTE-
FILTRE. IL EXISTE UN RESQUE DE BLESSURE SI LE PORTE-FILTRE SET
RELÂCHÉ SOUS PRESSION.

VORSICHT: DER LUFTFILTER IST UNTER DRUCK (4,1 BAR). DIE
LUFTZUFUHR MUSS ABGESTELLT UND DIE LEITUNGEN ZUM LUFTFILTER
ENTLEHRT WERDEN. ES BESTEHT VERLETZUNGSGEFAHR SOLLTE ER
UNTER DRUCK GEÖFFNET WERDEN.

1. Shut off the house air supply and depressurize the machine by disconnecting the 6 mm (¼”)

air hose from the bulkhead tube connector on the right side of the machine.

2. Open the right side door to access the drum.

3. Unscrew the threaded collar and carefully remove the bowl.

4. Clean (using mild soap and water only) and thoroughly dry all internal parts and the bowl

before reassembling.