2.4 DIP SWITCH SETTINGS

Open the cover of the DIP switches on the bottom
of the cradle in order to reach the DIP switches.
• Turn the DIP switch ON by moving it upwards.
• Turn the DIP switch OFF by moving it downwards.

Single cradle DIP switch settings:

Multicradle DIP switch settings:

* Set baud rate as in table below.
** In typical use keep cascade switch SW5 off.

User baud rate settings:

DIP
Switch

ON

OFF

SW 1

Baud rate *

Baud rate *

SW 2

Baud rate *

Baud rate *

SW 3

Baud rate *

Baud rate *

SW 4

Spare

SW 5

Spare

SW 6

Auto-baud
rate (PC-
controlled)

SW 1, 2, 3
determines
baud rate.

DIP
Switch

ON

OFF

SW 1

Baud rate *

Baud rate *

SW 2

Baud rate *

Baud rate *

SW 3

Baud rate *

Baud rate *

SW 4

RS232/
RS485

RS232 only

SW 5

Cascade **

SW 6

RS485
termination
ON

RS485
Termination
OFF

SW 7

Factory
setting

SW 8

Factory
setting

*) Baud rate

SW
1

SW
2

SW
3

2400

ON

OFF

OFF

4800

OFF

ON

OFF

9600 (default)

ON

ON

OFF

19200

OFF

OFF

ON

38400

ON

OFF

ON

57600

OFF

ON

ON

115200

ON

ON

ON