All reset, Continuous firing, Continuous firing all reset – Olympus FL-50 User Manual

Page 15

Advertising
background image

Continuous firings make the light-emitting section hot and may cause it to deteriorate or malfunc-
tion. Therefore, continuous firing should be limited to the counts shown in the following table.
Always leave the electronic flash unused for at least 10 minutes after continuous firing up to the
limit count.

CONTINUOUS FIRING

ALL RESET

All Reset resets the custom setups to the factory default settings.

• Press the MODE and LIGHT buttons simultaneously for 2

or more seconds to reset the custom setups (except for
the distance display unit (m/ft)) to the default settings.

• The distance display unit (m/ft) is not altered by the all

reset operation.

Limit counts of continuous firings

•Available counts of flash emission in synchronism with continuous shooting

The following table shows the flash emission count that can be synchronized to successive
shooting of the camera. Note, however, that the electronic flash should be left unused for more
than 10 minutes once the maximum continuous flash emission count has been reached.

Number of frames that can be synchronized successively

(assuming that the continuous shooting rate of the camera is 8 frames/sec.)

Light intensity ratio

External power supply

1/4

1/8

1/16

1/32

1/64

1/128

None

Batteries in FL-50

Flash Power Grip FP-1
(C/R14 alkaline batteries/
C/R14 Ni-Cd batteries)

High Voltage Pack HV-1
(Ni-Mh battery pack BN-1)

AA (R6) alkaline batteries

AA (R6) lithium batteries

AA (R6) Ni-Mn batteries

AA (R6) Ni-Cd batteries

AA (R6) Ni-Mh batteries

CR-V3 lithium battery pack

AA (R6) alkaline batteries

AA (R6) lithium batteries

AA (R6) Ni-Mn batteries

AA (R6) Ni-Cd batteries

AA (R6) Ni-Mh batteries

CR-V3 lithium battery pack

None

AA (R6) alkaline batteries

AA (R6) lithium batteries

AA (R6) Ni-Mn batteries

AA (R6) Ni-Cd batteries

AA (R6) Ni-Mh batteries

CR-V3 lithium battery pack

None

2

5

10

16

30

40

frames frames frames frames frames frames

4

40

40

40

40

40

frames frames frames frames frames frames

4

20

40

40

40

40

frames frames frames frames frames frames

Flash control mode

Flash intensity

Flash interval

Limit count

TTL AUTO
AUTO
MANUAL
FP AUTO
FP MANUAL

FULL; 1/1

1 sec.

10

1/2

0.5 sec.

20

1/4

0.3 sec.

40

1/8 to a/128

0.2 sec. or less

80

2

5

12

40

40

40

frames frames frames frames frames frames

2

5

16

18

40

40

frames frames frames frames frames frames