Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner

Buzzer Settings

ZZ

Start/End

Program

Menu

[[

VZ

Buzzer

after

transmission

W[

GD

Disable

startup buzzer

HE

GC

Enable startup

buzzer

HD

Buzzer Settings - These options determine the buzzer type, tone, duration and loudness. By default, the buzzer is disabled for
Linker type readers.
Buzzer Type - The buzzer may be disabled or enabled as either a hardware of software buzzer. Not all readers support both a
hardware and software buzzer.
Buzzer Tone - If a software buzzer is used, the buzzer tone may be selected.
Buzzer Duration and Volume - If a software buzzer is used, a buzzer duration of 50, 100, 200 or 400 msec. may be selected.
Volume may also be adjusted.
Buzzer Before Transmission - The good read buzzer will be activated after decoding the bar code, but before transmission.
During transmission, the buzzer sequence will be completed.
Buzzer After Transmission - The good read buzzer will be activated after transmission.
Enable Startup Buzzer - When this option is selected, the reader will generate a single good read buzzer to indicate the reader is
ready after the reader is supplied with power.
Disable Startup Buzzer - When this option is selected, the reader will not sound the buzzer after the reader is supplied with
power.