d. Conducted Transmit Power tolerances

Parameter

Conducted Tx Power

Note

GSM850 & GSM900 CS

+32dBm ±1dBm

GMSK mode, connectorized (Cl.4)

+27dBm ±1dBm

8PSK mode, connectorized (Cl.E2)

DCS1800 & PCS1900 CS

+29dBm ±1dBm

GMSK mode, connectorized (Cl.1)

+626Bm ±1dBm

8PSK mode, connectorized (Cl.E2)

UMTS1900 & 850 12.2Kbps

+23dBm ±1dBm

connectorized (Cl.3)

UMTS2100 12.2Kbps

+23dBm ±1dBm

connectorized (Cl.3)

e. Main antenna specifications

Frequency band

Network type

VSWR test frequency

(MHz)

(MHz)

824-894

GSM,GPRS,EDGE,UMTS

Low : 824

CDMA

Mid : 859
High : 894

880-960

GSM,GPRS,EDGE

Low : 880
Mid : 920
High : 960

1710-1880

GSM,GPRS,EDGE

Low : 1710
Mid : 1795
High : 1880

1850-1990

GSM,GPRS,EDGE,UMTS

Low : 1850

CDMA

Mid : 1920
High : 1990

1920-2170

UMTS

(Tx : 1920-1980)
Low : 1920
Mid : 1950
High : 1980
(Rx : 2110-2170)
Mid : 2110
Mid : 2140
Mid : 2170

The maximum antenna gain recommended, for consideration against RF exposure and
ERP/EIRP limits, is :

-

In Cellular band : 8dBi

-

In PCS band : 4dBi